| поискавой системы для электроныых деталей |
|
VSC8221XHH датащи(PDF) 78 Page - Microsemi Corporation |
|
|
|||||||||||||||||||||||||||||
VSC8221XHH датащи(HTML) 78 Page - Microsemi Corporation |
|
78 / 138 page ![]() VSC8221 Data Sheet VMDS-10106 Revision 4.1 December 2006 78 of 106 106 9.9 – 1000BASE-T FDX1 Since the VSC8221 is 1000BASE-T FDX capable, this bit is “1” by default. if bit 9.9 is written to be “0”, the auto-negotiation state machine for the local PHY will be blocked from advertising 1000BASE-T FDX. Note that the Link Partner will be notified of the state of bit 9.9 during auto-negotiation. After auto-negotiation is complete, changing the state of this bit has no effect unless auto-negotiation is manually restarted. 9.8 – 1000BASE-T HDX1 Since the VSC8221 is 1000BASE-T HDX capable, this bit is “1” by default. if bit 9.8 is written to be “0”, the auto-negotiation state machine for the local PHY will be blocked from advertising 1000BASE-T HDX. Note that the Link Partner will be notified of the state of bit 9.8 during auto-negotiation. After auto-negotiation is complete, changing the state of this bit has no effect unless auto-negotiation is manually restarted. 9.7:0 – Reserved 23.2.11 Register 10 (0Ah) – 1000BASE-T Status Register #1 10.15 – MASTER/SLAVE Configuration Fault2 This bit indicates whether a MASTER/SLAVE configuration fault has been detected by the local PHY. A configuration fault occurs if both the local and remote PHYs are forced to the same MASTER/SLAVE state, or if no resolution is reached after seven retries. When such a fault has been detected, this bit is set to “1”, but the PHY continues to renegotiate until the MASTER/SLAVE configuration is resolved. Once set, this bit is automatically cleared when (and only when) Register 10 is read via the SMi. 1The state of this register is internally latched when the auto-negotiation state machine enters the ABiLiTY_DETECT state. Changes to the states of these bits are recognized only at that time. This register is valid only in 1000BASE-T mode. Register 10 (0Ah) – 1000BASE-T Status Register #1 Bit Name Access States Reset Value Sticky 15 MASTER/SLAVE Configuration Fault RO LH SC 1 = MASTER/SLAVE configuration fault detected 0 = No MASTER/SLAVE configuration fault detected 0 14 MASTER/SLAVE Configuration Resolution RO 1 = Local PHY configuration resolved to MASTER 0 = Local PHY configuration resolved to SLAVE 1 13 Local Receiver Status RO 1 = Local receiver OK (loc_rcvr_status == OK) 0 = Local receiver not OK (loc_rcvr_status == NOT_OK) 0 12 Remote Receiver Status RO 1 = Remote receiver OK (rem_rcvr_status == OK) 0 = Remote receiver not OK (rem_rcvr_status == NOT_OK) 0 11 LP 1000BASE-T FDX Capability RO 1 = LP 1000BASE-T FDX capable 0 = LP not 1000BASE-T FDX capable 0 10 LP 1000BASE-T HDX Capability RO 1 = LP is 1000BASE-T HDX capable 0 = LP is not 1000BASE-T HDX capable 0 9:8 Reserved RO 00 7:0 idle Error Count RO SC 00000000 2This bit is valid only when the Page Received bit (6.1) is set to a “1” and if Mii Register bit 9.9 or 9.8 is set. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |