| поискавой системы для электроныых деталей |
|
INA229 датащи(PDF) 21 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
INA229 датащи(HTML) 21 Page - Texas Instruments |
|
21 / 40 page ![]() 7.6.1.1 Configuration (CONFIG) Register (Address = 0h) [reset = 0h] The CONFIG register is shown in Table 7-5. Return to the Summary Table. Table 7-5. CONFIG Register Field Descriptions Bit Field Type Reset Description 15 RST R/W 0h Reset Bit. Setting this bit to '1' generates a system reset that is the same as power-on reset. Resets all registers to default values. 0h = Normal Operation 1h = System Reset sets registers to default values This bit self-clears. 14 RSTACC R/W 0h Resets the contents of accumulation registers ENERGY and CHARGE to 0 0h = Normal Operation 1h = Clears registers to default values for ENERGY and CHARGE registers 13-6 CONVDLY R/W 0h Sets the Delay for initial ADC conversion in steps of 2 ms. 0h = 0 s 1h = 2 ms FFh = 510 ms 5 TEMPCOMP R/W 0h Enables temperature compensation of an external shunt 0h = Shunt Temperature Compensation Disabled 1h = Shunt Temperature Compensation Enabled 4 ADCRANGE R/W 0h Shunt full scale range selection across IN+ and IN–. 0h = ±163.84 mV 1h = ± 40.96 mV 3-0 RESERVED R 0h Reserved. Always reads 0. 7.6.1.2 ADC Configuration (ADC_CONFIG) Register (Address = 1h) [reset = FB68h] The ADC_CONFIG register is shown in Table 7-6. Return to the Summary Table. Table 7-6. ADC_CONFIG Register Field Descriptions Bit Field Type Reset Description 15-12 MODE R/W Fh The user can set the MODE bits for continuous or triggered mode on bus voltage, shunt voltage or temperature measurement. 0h = Shutdown 1h = Triggered bus voltage, single shot 2h = Triggered shunt voltage triggered, single shot 3h = Triggered shunt voltage and bus voltage, single shot 4h = Triggered temperature, single shot 5h = Triggered temperature and bus voltage, single shot 6h = Triggered temperature and shunt voltage, single shot 7h = Triggered bus voltage, shunt voltage and temperature, single shot 8h = Shutdown 9h = Continuous bus voltage only Ah = Continuous shunt voltage only Bh = Continuous shunt and bus voltage Ch = Continuous temperature only Dh = Continuous bus voltage and temperature Eh = Continuous temperature and shunt voltage Fh = Continuous bus, shunt voltage and temperature www.ti.com INA229 SLYS023 – DECEMBER 2020 Copyright © 2020 Texas Instruments Incorporated Submit Document Feedback 21 Product Folder Links: INA229 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |