| поискавой системы для электроныых деталей |
|
FN-3441 датащи(PDF) 2 Page - Schaffner International Ltd |
|
|
|||||||||||||||||||||||||||||
FN-3441 датащи(HTML) 2 Page - Schaffner International Ltd |
|
2 / 10 page ![]() 2 Ecosine passive Schaffner Group Datasheets 23 Oct 2020 Filter selection table – IP 00 enclosure Filter Rated load power Motor drive Rated filter Min. required Min. required Weight Typical Terminal Frame @ 400 V/50 Hz input current input current LDC LAC losses size [kW] [Arms]*** [Arms] [mH]***** [mH]***** [kg] [W]**** FN 3441-1-110-E0_ _ _ _ _* 1.1 1.7 1.62 37.41 9.8 6 53 110 A FN 3441-2-110-E0_ _ _ _ _* 2.2 3.4 3.23 18.71 6.01 9 73 110 A FN 3441-4-112-E0_ _ _ _ _* 4.0 6.2 5.9 10.29 3.48 12 104 112 B FN 3441-6-112-E0_ _ _ _ _* 5.5 8.5 8.1 7.483 2.548 15 143 112 C FN 3441-8-112-E0_ _ _ _ _* 7.5 12 11 5.487 1.818 16 193 112 C FN 3441-11-113-E0_ _ _ _ _ 11 17 16 3.741 1.264 23 233 113 D FN 3441-15-113-E0_ _ _ _ _ 15 23 22 2.744 0.909 26 285 113 D FN 3441-19-113-E0_ _ _ _ _ 19 29 28 2.166 0.724 30 271 113 D FN 3441-22-115-E0_ _ _ _ _ 22 34 32 1.871 0.637 38 355 115 E FN 3441-30-115-E0_ _ _ _ _ 30 46 44 1.372 0.454 43 452 115 E FN 3441-37-115-E0_ _ _ _ _ 37 57 54 1.112 0.361 48 468 115 E FN 3441-45-115-E0_ _ _ _ _ 45 70 66 0.915 0.297 54 596 115 E FN 3441-55-115-E0_ _ _ _ _ 55 85 81 0.748 0.245 63 665 115 E FN 3441-75-116-E0_ _ _ _ _ 75 116 110 0.549 0.178 98 757 116 G FN 3441-90-116-E0_ _ _ _ _ 90 140 133 0.457 0.147 106 854 116 G FN 3441-110-118-E0_ _ _ _ _ 110 171 162 0.374 0.12 127 1032 118 H FN 3441-132-118-E0_ _ _ _ _** 132 205 195 0.312 0.099 149 1062 118 H FN 3441-160-118-E0_ _ _ _ _** 160 249 238 0.257 0.085 167 1073 118 H FN 3441-200-118-E0_ _ _ _ _** 200 312 297 0.206 0.064 168 1228 118 H FN 3441-250-119-E0XXSXX 250 392 376 0.165 0.051 246 1398 119 J * Filter rating which does not require forced cooling or fan module ** Filter rating which does not require RC damping module for rectifiers with EMI filter *** Motor drive input current without harmonic filter ***** Typical losses @ 45°C, 400V, 50Hz and rated load power ***** In order to apply FN 3441 filters, motor drives have to be equipped with either DC-link choke or AC line choke. The minimum required inductance values are given in mH in the filter selection table. If neither DC-link choke nor AC line choke is present, or if the minimum mH rating is not fulfilled, FN 3441 filter must not be used. In this case, FN 3440 need to be chosen. Filter power terminals Terminal designation* Screw thread Flex wire AWG Flex wire Screw torque value Max width** Frame size cable lug [mm2] [Nm] [mm] 110 M3 14-22 0.4-2.5 0.5 7 A 112 M4 10-22 0.4-6 1.2 10 B, C 113 M6 6-18 0.75-16 3 15 D 115 M8 1/0-8 10-50 8 15 E, F 116 M8 3/0-8 10-95 8 17 G 118 M10 3/0-500 kcmil 95-240 10 35 H 119 M16 350-750 kcmil 185-400 10 48 J * Recommended connector type: wire or cable lug for 110 to 113, only cable lug for 115 to 119 ** To fulfill creepage/clearance acc. UL 61800-5-1 without additional protection (insulation). Creepage/clearance can vary depending on applicable standard and must be reviewed by customer. Creepage/clearance may be reduced when additional protection (insulation) is provided. Filter signal and earth terminals Terminal type Screw thread Screw torque value Frame size [Nm] Signal M3* 0.5 All Earth (PE) M5 2.2 A Earth (PE) M6 4 B, C Earth (PE) M8 9 D, E Earth (PE) M10 17 F, G, H Earth (PE) M12 25 J * Max width cable lug = 7 mm |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |