| поискавой системы для электроныых деталей |
|
GLM110 датащи(PDF) 2 Page - SL Power Electronics |
|
|
|||||||||||||||||||||||||||||
GLM110 датащи(HTML) 2 Page - SL Power Electronics |
|
2 / 2 page ![]() SL Power Electronics Corp, 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 Email: info@slpower.com Rev. 02/11/10. Data Sheet © 2010 SL Power Electronics Corp. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING Temperature (A) 0 to 50° -40 to +85°C Humidity (A) 0 to 95% RH 0 to 95% RH Shock (C) 20 g pk 40 g pk Altitude -500 to 10,000 ft -500 to 40,000 ft Vibration (B) 1.5 g rms’ 0.003 g 2 /Hz 5 g rms’ 0.026 g 2 /Hz GLC110/GLM110 MECHANICAL SPECIFICATIONS A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derated output current and toal output power by 2.5% per °C above 50°C. B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating. C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks. Commercial Model Medical Model RoHS Suffix* Output No. Output Output Minumum Output Normal (A) Forced Air (B) Output Peak Noise P-P OVP Total Regu- lation ( C ) GLC110-212 GLM110-212 G 1 +12 V 1 A 6.3 A 9.1 A 9.5 A 100 mV 15.6 ± 1.1 V 2% 2 -12 V 0 A 2.5 A 3 A 4 A 120 mV 2% GLC110-215 GLM110-215 G 1 +15 V 1 A 5 A 7.3 A 7.7 A 120 mV 18.5 ± 1.5 V 2% 2 -15 V 0 A 2.5 A 3 A 4 A 150 mV 2% GLC110-524 GLM110-524 G 1 +24 V 1 A 3.2 A 4.6 A 4.75 A 200 mV 28 ± 2.5 V 2% 2 +5 V 0 A 1.5 A 2 A 2.5 A 50 mV 6.2 ± 0.6 V 2% GLC110-12 GLM110-12 G 1 12 V 0 A 6.3 A 9.1 A 9.5 A 120 mV 15.6 ± 1.1 V 2% GLC110-15 GLM110-15 G 1 15 V 0 A 5 A 7.3 A 7.7 A 150 mV 18.5 ± 1.5 V 2% GLC110-24 GLM110-24 G 1 24 V 0 A 3.2 A 4.6 A 5 A 240 mV 28 ± 2.5 V 2% * Add “G” suffix to part number for RoHS compliant model. Contact factory for availability. A. Rating with unrestricted convection cooling. Total power not to exceed 75 W; no output can exceed rated current. B. Rating with 26 cfm forced air cooling. Total power not to exceed 110 W. C. To maintain regulation V1 current must be at least 1/5 of V2. V1 must not be adjusted more than 1% below nominal and have at least 10% of rated load. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |