| поискавой системы для электроныых деталей |
|
LDL40 датащи(PDF) 2 Page - CINCON ELECTRONICS Corporation |
|
|
|||||||||||||||||||||||||||||
LDL40 датащи(HTML) 2 Page - CINCON ELECTRONICS Corporation |
|
2 / 2 page ![]() V14 2 Specifications LDL40 Derating Curve INPUT SPECIFICATIONS: AC Input Voltage ………………......…............................................ 90~264Vac Frequency ………………………………………….……………..... 50/60 Hz AC Inrush Current ……….... <5A After 100μS @240Vac, 25℃ Ta Cold Start Standby Power Consumption ……..………………………………..…… <0.5W Leakage Current ………………………………………….……………. <0.75mA OUTPUT SPECIFICATIONS: Constant Current Accuracy (note1) ….…………...….……..…..…… ±5% max. Current Line Regulation (note2) ………….…………………..…….. ±5% max. Current Load Regulation (note3) ……………………………..…..…. ±5% max Over Voltage Protection …………..…………………………...…….TVS Clamp Short Circuit Protection ……………………..….. Hiccup Mode, Auto Recovery DALI Dimming (Option with Current Setting Resistor Between Pin3 and Pin4 of CN3) …………. 1~100% GENERAL SPECIFICATIONS: Efficiency …………………...…… LDL40DU:86%@230Vac Full Load. Isolation Voltage, Input to Output ………….…..……………………. 3.75KVac Isolation Resistance, Input to Output ………..………………..…..…10 8 Ω min. Surge Voltage Between L-N ………………..………………………………. 2KV SAFETY AND EMC: Safety ………………………………………………. EN61347-1,EN61347-2-13 EMI …………………………………………..……………….. EN55015 Class B EMS ………………………………………..…....... EN61000-4-2, 3, 4, 5, 6, 8,11 Harmonic Current …………………………………..…...…..… EN61000-3-2, 3 MECHANICAL CHARACTERISTICS: ENVIRONMENTAL CHARACTERISTICS: Dimensions …..………….. 5.906x3.150x0.913 Inches (150.0x80.0x23.2mm) Operating Ambient Temperature …...... -30℃~ 50℃ (See Derating Curve) Weight …………………………………….…………………………………. 220g Cooling…………………………………………………….Natural Convection NOTE: Storage Temperature, Humidity ……….…......... -40 ~ 85℃, 20%~95% RH 1. Set at 230Vac nominal input voltage and full load. Operating Altitude max. .……………………….. 3000 m Above Sea Level 2. Current line regulation is measured from high line to low line, full load. Temperature Coefficient ……………………………… ±0.05%/℃( 0~50℃) 3. Current load regulation is measured from min. output voltage to max. output voltage. 4. All specifications are typical at 230 Vac, Vo max., full load and 25˚C Ta. unless other noted Mechanical Specification |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |