19 / 39 page ![]() PCM4108 SBAS354 − JUNE 2005 www.ti.com 19 POWER-DOWN OPERATION The PCM4108 can be forced to a power-down state by applying a low level to the RST input for a minimum of 65,536 system clock cycles. In power-down mode, all internal clocks are stopped, and analog outputs are set to a high-impedance state. The system clock can then be removed to conserve additional power. In the case of a system clock restart when exiting the power-down state, the clock should be restarted prior to a low-to-high transition of the reset signal at the RST input. The low-to-high transition of the reset signal initiates a reset sequence, as described in the Reset Operation section of this data sheet. In Software mode, two additional power-down controls are provided. The PDN12 and PDN34 bits are located in Control Register 6 of Bank A and may be used to power-down channel pairs, with PDN12 corresponding to channels 1 and 2, and PDN34 corresponding to channels 3 and 4. The PDN56 and PDN78 bits are located in Control Register 6 of Bank B, with PDN56 corresponding to channels 5 and 6, and PDN78 corresponding to channels 7 and 8. This design allows the user to conserve power when a channel pair is not in use. The power-down function is the same as described in the previous paragraph for the corresponding channel pair. Unlike the power-down function implemented using the RST input, setting a power-down bit will immediately power down the corresponding channel pair. When exiting power-down mode, either by forcing the RST input high or by setting the corresponding control bits low, the analog outputs will transition from the high-impedance state to the mute state, with the output level set to the bipolar zero voltage. There may be a small transient created by this transition, since an internal capacitor charge can initially force the output to a voltage above or below bipolar zero, or external circuitry can pull the outputs to some other voltage level. Figure 8 illustrates the state of the analog outputs before, during, and after a power-down event. Analog Outputs 65,536 SCKI Periods Outputs are On Outputs are Muted RST 0V V DD Analog Outputs 1024 SCKI Periods Required for Initialization 1024 SCKI Periods Required for Initialization Outputs are On Outputs are On Outputs are On Outputs are High Impedance Outputs are High Impedance Outputs Transition from High Impedance to Muted State Outputs Transition from High Impedance to Muted State PDN12 PDN34 PDN56 PDN78 LO HI Outputs are On Transitioning to Driven State Figure 8. Analog Output State for Power-Down Operations |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |