| поискавой системы для электроныых деталей |
|
ALPHA2 датащи(PDF) 3 Page - Mitsubishi Electric Semiconductor |
|
|
|||||||||||||||||||||||||||||
ALPHA2 датащи(HTML) 3 Page - Mitsubishi Electric Semiconductor |
|
3 / 19 page ![]() ALPHA2 QUICK START MANUAL 3 1. INTRODUCTION The Alpha2 Series Controllers provides supervisory control for use in the home, office, factory, or wherever you need it. The Alpha2 Series Controllers offers flexible I/O control for varied applications including: • Automation of lights, air-conditioning, or watering systems • The opening and shutting of gates • Easy security systems • Domestic animal and pet food distribution systems • Control of stockyards and greenhouses However, the Alpha2 Series Controllers is not designed to be used in the following applications: • Applications where high reliabilities such as nuclear power control, railway facilities, airline facilities, vehicles, combustion equipment and medical equipment are required. • Applications in life critical situations 1.1 AVAILABLE MODELS Model No AL2- 10MR-A AL2- 10MR-D AL2- 14MR-A AL2- 14MR-D AL2- 24MR-A AL2- 24MR-D Power Supply 100-240V AC~ 24VDC 100-240V AC~ 24VDC 100-240V AC~ 24VDC Input Type 100 - 240V AC~ 24VDC Sink/ Source 100 - 240V AC~ 24VDC Sink/ Source 100 - 240V AC~ 24VDC Sink/ Source No. Inputs 6 6 8 8 15 15 Output Type Relay No. Outputs 4 4 6 6 9 9 Dimensions mm (in) 71.2 x 90 x 52 (2.8 x 3.54 x 2.05) 124.6 x 90 x 52 (4.91 x 3.54 x 2.05) Weight kg (lbs) 0.21 (0.47) 0.20 (0.44) 0.30 (0.66) 0.35 (0.77) 0.30 (0.66) 1.2 CAUTION CAUTION: Persons trained in the local and national electrical standards must perform all tasks associated with wiring the Alpha2 Series Controller. • Disconnect all terminals from power supply before removing the cover. • Turn off the power before performing any wiring operations. • Input and output cables should not be run through the same multicore cable or share the same wire. • Input and output cable length must be less than 30m (98' 5"). • The wire should be used a single cable, used a crimp terminal, or carefully twist stranded wires together. Do not connect a soldered wire end to the Alpha2 Series Controller. • To avoid damaging the wire, tighten to a torque of 0.5 - 0.6 N•m. • Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration. • The connectors must be covered to prevent contact with “live” wires. • The Alpha2 Series Controller must be installed in distribution box or a control cabinet. • Leave a minimum of 10mm of space for ventilation between the top and bottom edges of the Alpha2 Series Controller and the enclosure walls. • The Alpha2 Series is not designed to be used in life critical or fail safe applications. • Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage that may arise as a result of the installation or use of this equipment. • Please read this entire manual for further information. 2. DIMENSIONS Unit of Measure: mm (inch) AL2-14MR-_, AL2-24MR-_ AL2-10MR-_ 3 INSTALLATION n MOUNTING NOTES The Alpha2 Series’ safe design means the user can install it almost anywhere but please take the following points into consideration. • Do not install in areas with excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration. Do not place in water or let water leak onto the controller. • Do not allow debris to fall inside the unit during installation. • Keep as far as possible from high-voltage cables and power equipment. • The Alpha2 Series Controller must be installed in a distribution box or a control cabinet. OUT1 OK - + ESC OUT3 9 RELAY OUTPUT 6 5 OUT 8 OUT2 OUT4 7 DC INPUT 15 14 0 1 1 1 2 1 3 1 9 8 7 6 5 4 32 1 ) A ( ) B ( + - 24V DC POWER AL2-24MR-D 124.6(4.91") 6(0.24") 6(0.24") 52(2.05") + - E01 E02 4 0 E - 3 0 E + OUT4 OUT2 OUT3 OUT1 AL2-10MR-D OK ESC + - 1 2345 6 DC INPUT - + ) A ( ) B ( POWER 24V DC RELAY OUTPUT 71.2(2.8") 6(0.24") 6(0.24") 52(2.05") OUT1 OK - + ESC OUT3 9 RELAY OUTPUT 6 5 OUT 8 OUT2 OUT4 7 DC INPUT 15 14 0 1 1 1 2 1 3 1 9 8 7 6 5 4 32 1 ) A ( ) B ( + - 24V DC POWER AL2-24MR-D 124.6(4.91") 6(0.24") 6(0.24") 52(2.05") + - E01 E02 4 0 E - 3 0 E + OUT4 OUT2 OUT3 OUT1 AL2-10MR-D OK ESC + - 1 2345 6 DC INPUT - + ) A ( ) B ( POWER 24V DC RELAY OUTPUT 71.2(2.8") 6(0.24") 6(0.24") 52(2.05") Mitsubishi Electric Automation, Inc. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |