  LCM-40BLE Datasheet HTML 1Page - Mean Well Enterprises Co., Ltd. LCM-40BLE Datasheet HTML 2Page - Mean Well Enterprises Co., Ltd. LCM-40BLE Datasheet HTML 3Page - Mean Well Enterprises Co., Ltd. LCM-40BLE Datasheet HTML 4Page - Mean Well Enterprises Co., Ltd. LCM-40BLE Datasheet HTML 5Page - Mean Well Enterprises Co., Ltd. LCM-40BLE Datasheet HTML 6Page - Mean Well Enterprises Co., Ltd. LCM-40BLE Datasheet HTML 7Page - Mean Well Enterprises Co., Ltd. LCM-40BLE Datasheet HTML 8Page - Mean Well Enterprises Co., Ltd.  
Zoom Inzoom in Zoom Outzoom out
 4 / 8 page
background image
File Name:LCM-40BLE-SPEC 2019-08-13
40W Multiple-Stage Constant Current Mode LED Driver
LCM-40BLE
Push Button
AC/N
AC/L
DIMMING OPERATION
※Freely assignable (push) input
‧The LCM BLE series also has one freely assignable AC mains (push) input. As with a CASAMBI sensor module, control pulses can be defined here
(e.g. “controls a luminaire”; “controls an element”; “controls a group”; “controls scenes”; “controls all luminaires”; “change scenes”). See the reference
connection figure in the above.
※Casambi Bluetooth control
‧To be used through APP available on Apple Store and Play Store for iOS and Android.
PUSH
AC/N
AC/L
LCM-40BLE
AC mains
■APP SOFTWARE OVER TEMPERATURE PROTECTION
The real time Bluetooth IC temperature is shown in the APP. In case it reaches above 75 ºC (equivalent to Tc 90ºC), the driver will be turn off to provide a protection.
In case the units is cooled down, it can be manually turn ON and back to normal operation again.
NOTE: 1.This software temperature protection is an extra independent function from driver its own hardware over temperature protection(when it is enabled, it needs
re-AC power on to recover) and temperature compensation operation function described in the following section.
2.In general the software temperature protection is triggered before the hardware one when in over temperature.



Html Pages

1 2 3 4 5 6 7 8


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com