MAX7313 датащи(PDF) 7 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX7313 датащи(HTML) 7 Page - Maxim Integrated Products |
|
7 / 27 page ![]() as an input or an output. Reading an input ports regis- ter latches the current-input logic level of the affected eight ports. Transition detection allows all ports config- ured as inputs to be monitored for changes in their logic status. The action of reading an input ports regis- ter samples the corresponding 8 port bits’ input condi- tions. This sample is continuously compared with the actual input conditions. A detected change in input condition causes the INT/O16 interrupt output to go low, if configured as an interrupt output. The interrupt is cleared either automatically if the changed input returns to its original state, or when the appropriate input ports register is read. The INT/O16 pin can be configured as either an inter- rupt output or as a 17th output port with the same static or blink controls as the other 16 ports (Table 4). Port Output Control and LED Blinking The two blink phase 0 registers set the output logic lev- els of the 16 ports P0–P15 (Table 8). These registers control the port outputs if the blink function is disabled. A duplicate pair of registers, the blink phase 1 regis- ters, are also used if the blink function is enabled (Table 9). In blink mode, the port outputs can be flipped between using the blink phase 0 registers and the blink phase 1 registers using software control (the blink flip flag in the configuration register) (Table 4). PWM Intensity Control The MAX7313 includes an internal oscillator, nominally 32kHz, to generate PWM timing for LED intensity con- trol. PWM intensity control can be enabled on an out- put-by-output basis, allowing the MAX7313 to provide any mix of PWM LED drives and glitch-free logic out- puts (Table 10). PWM can be disabled entirely, in which case all output ports are static and the MAX7313 operating current is lowest because the internal oscilla- tor is turned off. PWM intensity control uses a 4-bit master control and 4 bits of individual control per output (Tables 13, 14). The 4-bit master control provides 16 levels of overall intensi- ty control, which applies to all PWM-enabled output ports. The master control sets the maximum pulse width from 1/15 to 15/15 of the PWM time period. The individual settings comprise a 4-bit number further reducing the duty cycle to be from 1/16 to 15/16 of the time window set by the master control. For applications requiring the same PWM setting for all output ports, a single global PWM control can be used instead of all the individual controls to simplify the con- trol software and provide 240 steps of intensity control (Tables 10 and 13). Standby Mode When the serial interface is idle and the PWM intensity control is unused, the MAX7313 automatically enters standby mode. If the PWM intensity control is used, the operating current is slightly higher because the internal PWM oscillator is running. When the serial interface is active, the operating current also increases because the MAX7313, like all I2C slaves, has to monitor every transmission. Serial Interface Serial Addressing The MAX7313 operates as a slave that sends and receives data through an I2C-compatible 2-wire inter- face. The interface uses a serial data line (SDA) and a serial clock line (SCL) to achieve bidirectional commu- nication between master(s) and slave(s). A master (typ- ically a microcontroller) initiates all data transfers to and from the MAX7313 and generates the SCL clock that synchronizes the data transfer (Figure 2). The MAX7313 SDA line operates as both an input and an open-drain output. A pullup resistor, typically 4.7k Ω, is required on SDA. The MAX7313 SCL line operates 16-Port I/O Expander with LED Intensity Control, Interrupt, and Hot-Insertion Protection _______________________________________________________________________________________ 7 Figure 2. 2-Wire Serial Interface Timing Details SCL SDA tR tF tBUF START CONDITION STOP CONDITION REPEATED START CONDITION START CONDITION tSU,STO tHD,STA tSU,STA tHD,DAT tSU,DAT tLOW tHIGH tHD,STA |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |