| поискавой системы для электроныых деталей |
|
CS625 датащи(PDF) 2 Page - Greystone Energy Systems Inc. |
|
|
|||||||||||||||||||||||||||||
CS625 датащи(HTML) 2 Page - Greystone Energy Systems Inc. |
|
2 / 2 page ![]() Specication: Setpoint Range...............................................1 - 175 Amps adjustable Maximum Input Current...............................175 Amps continuous Sensing Ranges...............................................Low (1-6 Amps) no-jumper Mid (6-40 Amps) High (40-175 Amps) Sensor Power...................................................Self-powered Output Type.....................................................Solid-state Output Switch Action....................................Normally open Output Switch Ratings..................................240 Vac, 1 Amp maximum Frequency.........................................................50/60 Hz Response Time................................................< 200 mS typical Insulation Class...............................................600 Vac, insulated conductors Operating Temperature................................-15 to 40 C (5 to 104 F) Operating Humidity.......................................5 to 90 %RH, non-condensing Terminal Block.................................................14 to 22 AWG Dimensions......................................................49 x 87 x 25 mm (1.95” x 3.45“ x 1”) Sensor Aperture..............................................20 mm (0.8 in) Enclosure Material......................................... ABS, UL94 V-0 Mounting Holes..............................................2 x 5 mm holes spaced 76 mm on base (2 x 0.19” holes spaced 3” on base) Agency Approvals..........................................cULus Listed Applications For applications with load currents exceeding the sensor current ranges use an external CT to reduce the current to an acceptable value. For example, to measure a 500 Amp load current, use a 500A:5A CT and wrap the CT secondary through the CS-625 and place the CS-625 in the low range. For applications with very small load currents (such as less than 1 Amp), wrap the monitored conductor through the sensor aperture several times to increase the current measured by the sensor. For example, to monitor a 0-1 Amp load with a CS-625, wrap the conductor through the sensor aperture 5 times so the sensor actually sees 0-5 Amps. Be careful the combined current of total of the wraps does not exceed the selected current range. For any application with multiple wraps, note that the CS-625 maximum current rating must be divided by the number of wraps. For example, with one wrap the maximum current is 175 Amps, with 5 wraps the maximum current is 175/5 = 35 Amps. Ensure the load current is < 35 Amps or the device may overheat and be damaged. Figure 6 Figure 7 49 mm (1.95”) 87 mm (3.45”) 25 mm (1.0”) 67.2 mm (3”) Ø 0.18” (x2) 5 mm Calibration With the sensor installed and range jumper set, turn on the monitored load (motor, heater, etc.) and allow it to run normally. Rotate the setpoint knob counterclockwise several times to make sure switch is open. Then slowly turn the knob clockwise until the switch closes. Turn clockwise slightly more to eliminate false switching. The CS is now set to detect a current condition. A voltmeter can be used across the contacts to verify switch operation. RELAY Power Source Typical Installation CS-625 Current Switch HIGH MID RANGE Amps 1-6 6-40 40-175 Jumper NONE MID HIGH Setpoint CCW To Increase Switch Rating 240 Vac 1 Amp 40C Max 20 mm (0.8”) Figure 5 CS-625 Current Switch HIGH MID RANGE Amps 1-6 6-40 40-175 Jumper NONE MID HIGH Setpoint CCW To Increase Switch Rating 240 Vac 1 Amp 40C Max Greystone Energy Systems, Inc. 150 English Drive, Moncton, NB E1E 4G7 Canada Tel: +1-506-853-3057 Tollfree (North America): +1-800-561-5611 Fax: +1-506-853-6014 Email: support@greystoneenergy.com Web: www.greystoneenergy.com |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |