3 / 8 page ![]() 0 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 250 200 150 100 50 Sensor Separation – Y (Meters) Horizontal Misalignment Vertical Misalignment Maximum Off-axis Distance – X (Millimeters) X Y X Y Figure 3. Maximum Off-Axis Misalignment Mounting The wide beam pattern of PVA emitters and receivers simplifies their alignment. M4 stainless steel fasteners and two stainless steel brackets are included with each sensor. Mount each emitter and its corresponding receiver parallel to one another in the same plane, with their cable ends pointing the same direction, and their tops and bottoms aligned. 1. From a common point of reference, make measurements to locate the emitter and receiver in the same plane with their midpoints directly opposite each other. 2. Mount the included brackets to the top and bottom of each sensor, as shown. 3. Mount the emitter and receiver in their brackets, being careful to position the red lenses of the two units directly facing each other. (Remember, the cable ends of both sensors must point in the same direction to ensure proper sensing.) 4. Measure from one or more reference planes (for example, the building or bin floor) to the same point(s) on the emitter and receiver to verify their mechanical alignment. (If the sensors are mounted exactly vertical or horizontal, a carpenter’s level may be helpful. A straightedge or a string extended between the sensors may also be helpful.) 5. Also check “by eye” for line-of-sight alignment. 6. Make any necessary final mechanical adjustments, and hand-tighten the bracket hardware. 7. After the electrical hookup is complete, check for beam alignment. If necessary, re-align the emitter and receiver at that time. Figure 4. PVA Mounting Hardware Hookups All models feature integral 2 m (6.5 ft) long, 3.3 mm (0.13 inch) dia. PVC-jacketed cables. Models whose model numbers end in “Q” are terminated with quick-disconnect (QD) Euro-style 4-pin connectors; other models have unterminated ends. Emitter with Unterminated Cable bn wh + - bu 12-30V dc Job Light Enable* Emitter with 4-Pin Euro QD bn wh + - bk bu 12-30V dc Job Light Enable* Receiver with NPN (Sinking) Output Receiver with PNP (Sourcing) Output bn bu - + bk wh 12-30V dc Job Light Enable* Load bn bu - + bk wh 12-30V dc Job Light Enable* Load Wiring is functionally identical for cabled and quick-disconnect receiver models. * See Configuration on page 4 for job light enable input requirements. NOTE: Blue wire (dc common) is internally connected to emitter and receiver housings. PVA Pick-to-Light Array P/N 52088 Rev. F www.bannerengineering.com - Tel: +1-763-544-3164 3 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |