поискавой системы для электроныых деталей
  Russian  ▼
ALLDATASHEETRU.COM

X  

BMP085 датащи(PDF) 18 Page - Bosch Sensortec GmbH

номер детали BMP085
подробное описание детали  Digital pressure sensor
PDF  27 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  BOSCH [Bosch Sensortec GmbH]
домашняя страница  https://www.bosch-sensortec.com
Logo BOSCH - Bosch Sensortec GmbH

BMP085 датащи(HTML) 18 Page - Bosch Sensortec GmbH

Back Button BMP085 Datasheet HTML 14Page - Bosch Sensortec GmbH BMP085 Datasheet HTML 15Page - Bosch Sensortec GmbH BMP085 Datasheet HTML 16Page - Bosch Sensortec GmbH BMP085 Datasheet HTML 17Page - Bosch Sensortec GmbH BMP085 Datasheet HTML 18Page - Bosch Sensortec GmbH BMP085 Datasheet HTML 19Page - Bosch Sensortec GmbH BMP085 Datasheet HTML 20Page - Bosch Sensortec GmbH BMP085 Datasheet HTML 21Page - Bosch Sensortec GmbH BMP085 Datasheet HTML 22Page - Bosch Sensortec GmbH Next Button
Zoom Inzoom in Zoom Outzoom out
 18 / 27 page
background image
BMP085
Data sheet
Bosch Sensortec
Rev. 1.2
Page 18
15 October 2009
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such
as copying and passing on to third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Specifications are subject to change without notice.
S
ACKS
Module address
write 0xEE
ACKS
Register address
e.g. 0xF6
MSB e.g.
ADC result 0x5C
ACKS
Module address
read 0xEF
Restart
ACKM
LSB e.g.
ADC result 0x96
NACKM
SCL
SDA
P
4.5 Read A/D conversion result or E
2PROM data
To read out the temperature data word UT (16 bit), the pressure data word UP (16 to 19 bit) and
the E
2PROM data proceed as follows:
After the start condition the master sends the module address write command and register
address. The register address selects the read register:
E
2PROM data registers
0xAA to 0xBF
Temperature or pressure value UT or UP
0xF6 (MSB), 0xF7 (LSB), optionally 0xF8 (XLSB)
Then the master sends a restart condition followed by the module address read that will be
acknowledged by the BMP085 (ACKS). The BMP085 sends first the 8 MSB, acknowledged by
the master (ACKM), then the 8 LSB. The master sends a "not acknowledge" (NACKM) and
finally a stop condition.
Optionally for ultra high resolution, the XLSB register with address 0xF8 can be read to extend
the 16 bit word to up to 19 bits; refer to the application programming interface (API) software
rev. 1.1 (“BMP085_SMD500_API”, available from Bosch Sensortec).
Timing diagram read 16 bit A/D conversion result:



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com