| поискавой системы для электроныых деталей |
|
SARS датащи(PDF) 1 Page - Sanyou Corporation Limited |
|
|
|||||||||||||||||||||||||||||
SARS датащи(HTML) 1 Page - Sanyou Corporation Limited |
|
1 / 3 page ![]() Model Max. continuous current Max. switching current Max. switching voltage SARS 35A connect (NO):150A , disconnect(NO):35A see performance curve Contact Capacity Characteristic Data 1/3 SARS-Series Features ● 35A switching capability. ● NO type and CO type are avaliable ● Satisfy RoHS and ELV SANYOU RELAYS Relays for advanced technology Automotive Relay version:V1.4 (1) (2) Model Max. continuous current Max. switching current Max. switching voltage SARS 35A connect (NO):150A , disconnect(NO):35A see performance curve (1) (2) Contact Data 2 AgSnO 2 on 14VDC resistive Contact Voltage Load Type Contact Current(A) 35 35 duty factor endurance (cycles) contact material test ambient 1C﹑1A NO NC OFF S off 23℃ 20 20 2 ON S 1x10 5 2 AgSnO 2 on lamp load 150 off 2 1x10 5 30 2 AgSnO 2 on general 80 off 2 1x10 5 30 Note: If the load condition is not in the table. Please contact SANYOU with load details to get more support (at 10,800 ops./h) 1x10 see contact parameter table Contact material contact voltage drop Operate time Release time Initial insulation resistance Initial dielectric strength Vibration resistance Shock resistance Endurance Ambient temperature Note: Silver alloy 200mv/at 10A (max) 10msec. Max. 10msec. Max. 100MΩ Min.(DC500V) Between open contacts: AC500V, 50/60Hz 1min. Between coil and contact: AC500V, 50/60Hz 1min. Mechanical Electrical -40℃~+125℃ (no condensation) Approx. 17.5 g 10~25Hz 1.27mm double-amplitude 25~500Hz 98m/s2 NO 20G/ NC 5G (3)Rated voltage step up to 0VDC,And measurement without coil suppression circuit; 7 (5) (6) (3) mechanical behavior Cover retentivity :(pull and press)≥200N Terminals retentivity :( )≥100N pull and press Terminals bending stiffness :(all directios)≥10N Unit weight (2) ,14VDC; surge current in lamp load ( 1)For the normally open contact,the measurement of the 100% rated voltage is applied to the coil (4)The leakage current is less than 1mA; (4) (5)When the excitation is excited,the opening time of the normally open contact is less than 1ms;when no excitation,the normally closed contact time is less than 1ms,at the same time,the normally open contact can not be closed; (6)Test point for the distance 2mm from the end foot,when the test force is removed,the lead foot should be less than 0.5mm ; temperature |
Аналогичный номер детали - SARS |
|
Аналогичное описание - SARS |
|
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |