11 / 39 page ![]() FS9721_LP3 Rev. 2.1 11/39 FLCD LCD Frame Frequency 32 Hz VLCD LCD Pk-Pk Driver Voltage 2.8 3 3.2 V FBEEP Beeper Frequency 2.7 kHz FRS232 RS232 Baud Rate 2400 bit IRSOUT RS232 Output High Current VOH=2V 2 mA Zero Input Reading DC ADPxl Input=0V -0.001 0.000 0.001 Linearity (Max. Deviation From Best Straight Line Fit DC ADPxl, Input,Full Scale±240.0mV -1 0 +1 Counts AC Measurement Bandwidth Error AC ADPxl Input240mVrms 20Hz~1kHz 0.2 % Rcc Continuity Check Value 10 60 Ohm ADC Measurement O.L Display Count 4050 Counts Autorange Up Counts 4000 Counts Autorange Down Counts 360 Counts VFREA Frequency Counter Input Level (Hz/Duty Control) VIL(Relative to AGND) -60 mV VIH(Relative to AGND) 60 mV FMAXA Frequency Counter Max Input frequency (Hz/Duty Control) Vpp=±100mV Square Wave Input 500k Hz *1 Duty Measurement Min Pulse Width Error (Hz/Duty Control) Vpp=±100mV Square Wave Input 1 μS VFRED Frequency Counter Input Level (MEAS=0101) VIL(Relative to AGND) -600 mV VIH(Relative to AGND) 600 mV FMAXD Frequency Counter Input Level (MEAS=0101) Vpp=±600mV Square Wave Input 5M Hz *1 Duty Measurement Min Pulse Width Error(MEAS=0101) Vpp=±600mV Square Wave Input 100 nS Capacitor Measurement Accuracy after Zero Input Relative. To adjust with 512.0nF Mode Standard 51.20 nF Mode 2%+10 Counts 512.0 nF Mode 0.5%+3 Counts 5.120 μF Mode 1%+2 Counts 51.20 μF Mode 1.5%+2 Counts *1 If input square wave during duty cycle measurement, then the deviation is mainly from the analyzable pulse width of the comparator itself. If the value is an input 100kHz square wave, we can divide the square wave into 1000 parts (1000Counts), and each part is 10nS. Therefore the largest deviation in duty cycle measurement is (100nS/10nS)=10Counts. The output 50.0% signal may be measured 50.0%±1.0%, and the signal that larger than 99% or smaller than 1% may not be measured, then it will display 0.00%. 10. Measurement Mode Select 10.1 Measurement Mode Select (MEA1〜MEA4: Open is “1”; Connect to VSS is “0”) ME A4 ME A3 ME A2 ME A1 Measurement Function and SELECT Key Function Switch Hz/Duty Rel Hold Range Select Jumper ① 1 1 1 1 ② DCV/ACV DCV/ACV Switch V/Hz/Duty Switch ● ● ● ● J4 1 1 0 1 Ohm/Diode/Co nt./Cap CAP=1:Ohm/ Diode /Cont. Switch CAP=0:Ohm/ Diode/Cont. /Cap Switch ● ● Ohm ● ● J3, J5 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |