2 / 16 page ![]() GPM AT TOTAL FEET Model 10 15 20 No flow at height shown below CAPACITY GALLONS/MINUTE S40HT-11P 42 30 10 21 S40HT-11* 42 30 10 21 S50HTPC1 65 — 60 48/50 *Performance is reduced with high temp liquids. INSTALLATION Hazardous voltage. Can shock, burn or kill. Do not lift pump by the power cord. See “Cord Lift Warning” on Page 3. NOTICE: Install the pump on a hard, level surface (cement, asphalt, etc.). Never place the pump directly on earth, clay or gravel surfaces. Piping Piping must not be smaller than pump discharge. When installed in an effluent system, the pipe must be capable of handling semi-solids of at least 3/4" (19mm) in diameter. The rate of flow in the discharge pipe must keep any solids present in suspension in the fluid. To meet minimum flow requirements (2 feet per second in the discharge line), size the pipe as follows: A Pipe Size Of: Will Handle a Flow Rate Of: 1-1/2" (38mm) 12 GPM 2" (51mm) 21 GPM 2-1/2"(64mm) 30 GPM 3"(76mm) 48 GPM In an effluent system use a 1-1/2" (38mm) check valve in pump discharge to prevent backflow of liquid into sump basin. The check valve should be a free flow valve that will easily pass solids. Be sure check valve installation complies with local codes. NOTICE: For best performance of check valve when handling solids, do not install it with the discharge more than 45° above the horizontal. Do not install the check valve in a vertical position as solids may settle in the valve and prevent it from opening on startup. Drill a 3/16" (5mm) hole in the discharge pipe about 1–2" (25-51mm) above the pump discharge connection (but below check valve) to prevent airlocking the pump. Electrical Hazardous voltage. Can shock, burn, or kill. When installing, operating, or servicing this pump, follow the safety instructions listed below. 1. DO NOT splice the electrical power cord. 2. DO NOT allow the electrical cord plug to be submerged. 3. DO NOT use extension cords. They are a fire hazard and can reduce voltage sufficiently to prevent pumping and/or damage motor. 4. DO NOT handle or service the pump while it is connected to the power supply. 5. DO NOT remove the grounding prong from the plug or modify the plug. To protect against electrical shock, the power cord is a three-wire conductor and includes a 3-prong grounded plug. Plug the pump into a 3-wire, grounded, grounding-type receptacle. Connect the pump according to the NEC or CEC and local codes. For automatic operation, plug or wire the pump into an automatic float switch or duplex controller. The pump will run continuously when plugged directly into an electrical outlet. S50HTPC1 requires switch panel PW217-280. Connect or wire pump to its own individual branch circuit with no other outlets or equipment in the circuit. Size fuses or circuit breakers according to the “Motor, Switch and Cord Specifications” chart. Risk of electrical shock and fire. Can burn, kill or cause property damage. Be sure that power supply information (Voltage/ Hertz/Phase) on pump motor nameplate matches incoming power supply exactly. Install pump according to all electrical codes that apply. Pumping Range (Inches) 610141822263034 38" 5.5" 6 10 14 18 22 26" 3.5" 413 0893 Performance Graph – Tether Length vs. Pumping Range OPERATION The automatic float switch on Model S50HTPC1 is factory set with a 4" tether length. This tether length can be adjusted to accommodate a variety of pumping ranges. (See performance graph.) The installer must ensure that the switch does not become obstructed and that the range is set so the liquid level remains a minimum of 2" above pump suction at the lowest level, and below the basin inlet pipe at the highest level. Risk of fire or explosion. Can cause severe personal injury, property damage or death. Do not use in explosive atmospheres. Pump water only with this pump. NOTICE: Do not allow the pump to run in a dry sump. It will void the warranty and may damage the pump. An automatic overload protector in the motor will protect the motor from burning out due to overheating/overloading. When the motor cools down, the overload protector will automatically reset and start the motor. If the overload trips frequently, check for the cause. It could be a stuck impeller, wrong/low voltage, or an electrical failure in the motor. If an electrical failure in the motor is suspected, have it serviced by a competent repairman. The pump is permanently lubricated. No oiling or greasing is required. 2 PERFORMANCE |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |