| поискавой системы для электроныых деталей |
|
LMV321TP датащи(PDF) 13 Page - 3PEAK INC. |
|
|
|||||||||||||||||||||||||||||
LMV321TP датащи(HTML) 13 Page - 3PEAK INC. |
|
13 / 18 page ![]() 13 LMV321TP/LMV358TP/LMV324TP 40μA, 1.27MHz, Micro-Power Rail-to-Rail I/O Op Amps www.3peakic.com.cn REV A.02 R1 1M Ω R2 1M Ω C1 400pF C2 400pF R3 2M Ω R4 2M Ω VIN VOUT 12 12 -3dB 3 4 3 4 R = R = R = 1M C = C = C = 400pF Q = Filter Peaking Factor = 1 f = 1/(2 ) = 400 R = R /(2-1/Q) ; with Q = 1, R =R RC Hz Figure 8 Portable Gas Sensor Amplifier Gas sensors are used in many different industrial and medical applications. Gas sensors generate a current that is proportional to the percentage of a particular gas concentration sensed in an air sample. This output current flows through a load resistor and the resultant voltage drop is amplified. Depending on the sensed gas and sensitivity of the sensor, the output current can be in the range of tens of microamperes to a few milli-amperes. Gas sensor datasheets often specify a recommended load resistor value or a range of load resistors from which to choose. There are two main applications for oxygen sensors – applications which sense oxygen when it is abundantly present (that is, in air or near an oxygen tank) and those which detect traces of oxygen in parts-per-million concentration. In medical applications, oxygen sensors are used when air quality or oxygen delivered to a patient needs to be monitored. In fresh air, the concentration of oxygen is 20.9% and air samples containing less than 18% oxygen are considered dangerous. In industrial applications, oxygen sensors are used to detect the absence of oxygen; for example, vacuum-packaging of food products. The circuit in Figure 9 illustrates a typical implementation used to amplify the output of an oxygen detector. With the components shown in the figure, the circuit consumes less than 37 μA of supply current ensuring that small form-factor single- or button-cell batteries (exhibiting low mAh charge ratings) could last beyond the operating life of the oxygen sensor. The precision specifications of these amplifiers, such as their low offset voltage, low TC-VOS, low input bias current, high CMRR, and high PSRR are other factors which make these amplifiers excellent choices for this application. 100 k Ω 1% 100 Ω 1% VOUT 100 k Ω 1% 10 M Ω 1% 2 O I 2 1 in Air ( 21% O ) 0.7 OUT DD VV I uA Oxygen Sensor City Technology 4OX2 Figure 9 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |