33 / 49 page ![]() preliminary preliminary iC-PI PROGRAMMABLE 12-BIT Sin/Cos INTERPOLATION IC WITH RS422 DRIVER Rev B1, Page 33/48 SINE-TO-DIGITAL CONVERSION SELRES Addr. 0x21, bit 6:0; Addr. 0x20, bit 7:0 Value STEP Angle Steps Per Period IPF Interpolation Factor fin()max* Permissible Input Frequency (@ MTD) 0x0003 4 1 300 kHz 0x0007 8 2 300 kHz 0x000F 16 4 300 kHz 0x0013 20 5 300 kHz 0x001F 32 8 300 kHz 0x0027 40 10 300 kHz 0x003F 64 16 300 kHz 0x004F 80 20 300 kHz 0x0063 100 25 300 kHz 0x007F 128 32 300 kHz 0x009F 160 40 250 kHz 0x00C7 200 50 200 kHz 0x00FF 256 64 159 kHz 0x018F 400 100 100 kHz 0x01F3 500 125 80 kHz 0x01FF 512 128 75 kHz 0x031F 800 200 50 kHz 0x03E7 1000 250 40 kHz 0x03FF 1024 256 38 kHz 0x07CF 2000 500 20 kHz 0x07FF 2048 512 19 kHz 0x0F9F 4000 1000 10 kHz 0x0FFF 4096 1024 9 kHz Notes Other settings are not allowed. *) According to Figure 4, page 12. Table 45: Converter Resolution iC-PI’s converter resolution is selected with SELRES. For a resolution of 4, four angle steps per input cycle are generated so that the output frequency at A and B matches the sine frequency at the inputs. The programmable converter hysteresis is determined by SELHYS. It is set in multiples of the increment size and has a maximum of 45° of the input signal period. SELHYS Addr. 0x1F, bit 3:0 Code Function Code Function 0x0 nearly none 0x8 2.0° 0x1 0.09° 0x9 4.0° 0x2 0.18° 0xA 6.0° 0x3 0.36° 0xB 8.0° 0x4 0.54° 0xC 10.0° 0x5 0.72° 0xD 11.25° 0x6 1.0° 0xE 22.5° 0x7 1.5° 0xF 45° Table 46: Converter Hysteresis STUPCNT Addr. 0x21, bit 4 Code Function 0x0 Count from zero angle: burst output to absolute position within input cycle. 0x1 Suppress edges on ABZ. Duration dependent on the Minimum Edge Distance (MTD). Using the largest MTD, the process lasts up to 15 ms. Table 47: Converter Startup HOLDCNT Addr. 0x21, bit 5 Code Function 0x0 No Hold on min. amplitude error 0x1 Hold on min. amplitude error Table 48: Converter Hold on Amplitude Error PA PB PZ AERR NORMAL HOLD NORMAL STARTUP Figure 17: Modes for count signals Figure 17 shows the device’s behavior during the op- tional startup and hold modes. STARTUP: When leaving the reset state, the interpola- tor counts up from zero angle to the applied angle posi- tion, at the maximum possible tracking frequency. The bit STUPCNT defines whether the internally counted signals are output at the pins (STUPCNT = 0), or su- pressed (STUPCNT = 1). NORMAL: After settling, the interpolator tracks the ap- plied input angle in normal mode. HOLD: In case of a signal error (loss of signal), the sine-to-digital converter is set on hold and no further count pulses can be seen at the outputs (HOLDCNT = 0). NORMAL: As soon as the amplitude returns back to regular levels, the converter continues counting from the last value and generates as many pulses as re- quired to catch up to the actual position. In doing so, the outputs show the configured minimum edge dis- |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |