3 / 7 page ![]() ICS726A 12 TO 36 MHZ 6TSOT VCXO VCXO IDT® 12 TO 36 MHZ 6TSOT VCXO 3 ICS726A REV E 021312 The third overtone mode of the crystal and all spurs must be >100 ppm distant from the 3x fundamental resonance measured with a physical load of 8.6pF. The external crystal must be connected as close to the chip as possible and should be on the same side of the PCB as the ICS726A. There should be no vias between the crystal pins and the X1 and X2 device pins. There should be no signal traces underneath or close to the crystal. See application note MAN05. Crystal Tuning Load Capacitors The crystal traces should include pads for small fixed capacitors, one between X1 and ground, and another between X2 and ground. The need for these capacitors is determined at system prototype evaluation, and is influenced by the particular crystal used (manufacture and frequency) and by PCB layout. The typical required capacitor value is 1 to 4 pF. To determine the value of the crystal capacitors: 1. Connect VDD of the ICS726A to 3.3 V. Connect pin 5of the ICS726A to the second power supply. Adjust thevoltage on pin 5 to 0V. Measure and record the frequency ofthe CLK output. (f0V) 2. Adjust the voltage on pin 5 to 3.3 V. Measure and record the frequency of the same output. (fhigh) Errorxtal = actual initial accuracy (in ppm) of the crystal being measured. If the centering error is less than ±25 ppm, no adjustment is needed. If the centering error is more than 25 ppm negative, the PC board has excessive stray capacitance and a new PCB layout should be considered to reduce stray capacitance. (Alternately, the crystal may be re-specified to a higher load capacitance. Contact IDT for details.) If the centering error is more than 25 ppm positive, add identical fixed centering capacitors from each crystal pin to ground. The value for each of these caps (in pF) is given by: = 2 x (centering error)/ (trim sensitivity) Trim sensitivity is a parameter which can be supplied by your crystal vendor or calculated using the following formula: |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |