| поискавой системы для электроныых деталей |
|
MP6536 датащи(PDF) 5 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP6536 датащи(HTML) 5 Page - Monolithic Power Systems |
|
5 / 10 page ![]() MP6536 - 26V, 5.5A 3-CHANNEL POWER HALF-BRIDGE MP6536 Rev. 1.01 www.MonolithicPower.com 5 5/3/2018 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2018 MPS. All Rights Reserved. PIN FUNCTIONS Pin # Name Description 1,2 SW2 Output 2. SW2 is valid approximately 100µs after VSP goes high. 3,4,5 VSP Power Supply Input. Connect VSP to the positive side of the input power supply. Bypass VSP to PGND as close to the IC as possible. 6,7 SW1 Output 1. SW1 is valid approximately 100µs after VSP goes high. 8,9 LS1 Low-Side Source Connection of SW1. 10 BST1 Bootstrap Supply. BST1 powers the high-side gate of the SW1 stage. Connect a capacitor ( 0.1μF or greater) between BST1 and SW1. 11 NC No Connection. NC MUST be kept floating. 12 PWM1 Driver Logic Input 1. Drive PWM1 with the signal that controls SW1. Drive PWM high to turn on the high-side switch; drive PWM low to turn on the low-side switch. 13 PWM2 Driver Logic Input 2. Drive PWM2 with the signal that controls SW2. Drive PWM high to turn on the high-side switch; drive PWM low to turn on the low-side switch. 14 FAULTB Fault Output. A low output at FAULT indicates that the MP6536 has detected an over- temperature, over-current, or under-voltage condition. FAULTB is an open-drain output. 15 SHDNB Shutdown Input. When SHDNB is low, the IC shuts off. 16 PWM3 Driver Logic Input 3. Drive PWM3 with the signal that controls SW3. Drive PWM high to turn on the high-side switch; drive PWM low to turn on the low-side switch. 17 STBYB Standby Input. Default low (internal pull-down). If driven high, the output of the driver is determined by PWM1/2/3. If driven low, all outputs are high impedance. 18 AGND Analog Ground. 19 FLT3B Fault Monitor. For details see the “Fault Output” section. FLT3B is an open-drain output. 20 FLT2B Fault Monitor. For details see the “Fault Output” section. FLT2B is an open-drain output. 21 NC No Connection. NC MUST be kept floating. 22, 23 PGND Power Ground. Connect the exposed pad on the bottom side to ground plane. 24, 25 NC No Connection. NC MUST be kept floating. 26,27, 28 VSP Power Supply Input. Connect VSP to the positive side of the input power supply. Bypass VSP to PGND as close to the IC as possible. 29, 30 SW3 Output 3. SW3 is valid approximately 100µs after VSP goes high. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |