| поискавой системы для электроныых деталей |
|
PB1005AC датащи(PDF) 1 Page - Vicor Corporation |
|
|
|||||||||||||||||||||||||||||
PB1005AC датащи(HTML) 1 Page - Vicor Corporation |
|
1 / 4 page ![]() Northwest Power, Inc. (503)-652-6161 www.npi-inc.com Document No. 6997 Rev H Print Date: 2014-05-19 Page 1 of 4 PB1005AC(-F)(-G)(-H)(-HE) Data Sheet Power Bank PB1005AC(-F)(-G)(-H)(-HE) AC/DC Power Supply Up to 5 Outputs 1000W Low-Profile 1.68" All specifications are at nominal input, full load, 25°C, all models, unless otherwise noted. Input Model -F -G -H -HE Nominal Input Voltage 115VAC 1 115/230 VAC 230VAC/300VDC 230VAC Input Voltage Range 95-132VAC 95-132VAC or 180-264VAC 180-264VAC or 250-375VDC 180-264VAC AC Input Frequency 47-440Hz 47-440Hz 47-440Hz 47-440Hz Voltage Sag Immunity to SEMI F47-0200 No No No Yes Hold-Up Time (Max Load, Nominal Line, Typical) 20 ms 20 ms 20ms 30ms Input Fuse (Internal) 20 A 15 A 20A 20A Inrush Current (264 VAC peak line, cold start.) 30Apk,max 30Apk,max 200Apk,typical 200Apk,typical Power Factor (typical) 0.60 Output 2 Output # A B C D E Maximum Output Current (Connector Limit) 80A 18A 40A Output Voltage (Factory configurable) 1.8 to 52V 1.8 to 52V Output Voltage Setpoint (50% load) ±1.2% ±1.2% Load Regulation, No load to full load (max.) ±0.2% ±0.5% Line Regulation, Low Line to High Line (max.) ±0.2% ±0.5% Maximum Output Power 500W 150W Remote Sense Yes No Output Ripple and Noise See individual Vicor modules specifications. Enable/inhibit function will affect this output Yes or No (Configurable for each output individually at the factory.) Trim range 10% to 110% of module nominal Vo 3 N/A Environmental Operating Temperature Range -20°C to 70°C Storage Temperature Range -40°C to 70°C Relative Humidity 5% -95% non-condensing Safety Important (!): Does not apply to (-F) operating at 230VAC Agency Approvals cTUVus, CE Safety Standard Compliance EN60950 Primary-to-Secondary Primary-Earth Secondary-Earth Isolation 3,000Vrms 1,500Vrms 250Vrms 1 Model -F will operate at 230VAC, but operation at 230VAC has not been evaluated for safety purposes. 2 Output voltage, current and power are limited to Vicor modules available. 3 Minimum load may be required to trim below 90%. Contact factory for details. |
Аналогичный номер детали - PB1005AC |
|
Аналогичное описание - PB1005AC |
|
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |