| поискавой системы для электроныых деталей |
|
AS39513 датащи(PDF) 57 Page - ams AG |
|
|
|||||||||||||||||||||||||||||
AS39513 датащи(HTML) 57 Page - ams AG |
|
57 / 108 page ![]() ams Datasheet Page 57 [v1-10] 2018-Apr-25 Document Feedback AS39513 − Detailed Description BTYPE[2:0] – Battery type algorithm to use. 3’b000 = Battery voltage is assumed to be nominally 1.5 V. 3’b001 = Battery voltage is assumed to be nominally 3.0 V. If the BTYPE value is changed for example from 3V type to 1.5V type, the new BTYPE value will only take effect after the next power up of the chip. The temperature sensor accuracy is only guaranteed if the chip is operated with a battery corresponding to the BTYPE it was tested with. BCKSEL[1:0] – Battery compare threshold. Threshold also depends on whether the battery is a 3 V or 1.5 V type as determined by the BTYPE[2:0] above. This is mapped directly to bchk_sel_o. When BTYPE is set for 1.5V batteries, BCKSEL can only have the default value BCKSEL[1:0] = 00. Please see Figure 10 for the battery check threshold values. TSMEAS – Enable temperature sensor logging. 0 = No temperature measurements. 1 = During logging, temperature measurements are made and optionally recorded depending on the logging mode. BVMEAS – Enable an ADC measurement of the battery voltage. 0 = No ADC measurement of the battery voltage is made or logged. 1 = Enable ADC measurement and logging of the battery voltage. EXMEAS – Enable external sensor logging. 0 = No external sensor measurements. 1 = During logging, external sensor measurements are made and optionally recorded depending on the logging mode. EIEN – Enable external sensor interrupt. 0 = No external sensor interrupt. 1 = External sensor interrupt can trigger a logging event. Interrupt will be triggered when the voltage on the SEXT pin falls below the threshold defined by EXIVSET. Interrupt is falling-edge sensitive, so the SEXT pin must rise above the threshold before an additional sensor interrupt can be triggered. LOGMD[1:0] – Logging mode for all sensors. 2’b00 – Dense mode. Logging will occur for all logging events. No measurement count or real-time clock values will be logged. 2’b01 – Interrupt mode. Logging will occur for all logging events. Sensors are always logged to 10-bit accuracy. The real-time clock value and interrupt source are logged. The interrupt source is a two-bit value: 2’b01 = external sensor interrupt, and 2’b10 = DIN interrupt. 2’b10 – Normal limit mode. Enable logging if any of the limit check conditions are met. Sensors are always logged to 10-bit accuracy. If a measurement is logged, the value of the measurement counter is also logged. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |