| поискавой системы для электроныых деталей |
|
LTC7003 датащи(PDF) 13 Page - Linear Technology |
|
|
|||||||||||||||||||||||||||||
LTC7003 датащи(HTML) 13 Page - Linear Technology |
|
13 / 24 page ![]() LTC7003 13 7003f For more information www.linear.com/LTC7003 APPLICATIONS INFORMATION Cooldown Period and Restart As soon as TIMER reaches 1.4V, TGDN is pulled to TS in an overcurrent fault condition and the TIMER pin starts dis- charging with a 2.5µA current. When TIMER reaches 0.4V, TIMER charges with a 2.5µA current. When TIMER reaches 1.4V, it starts discharging again with a 2.5µA current. This pattern repeats 32 times to form a long cooldown timer period (TCOOL_DOWN) before retry (Figure 5). If INP is cycled low, TGDN will be pulled to TS and TIMER will be pulled low with an internal 100kΩ resistor. If INP is cycled low during the cooldown period, the timer counter will be reset. If INP then goes high, TGUP will pulled to BST and the fault timer will be reactivated with the TIMER voltage starting from it’s current value. At the end of the cooldown period (when TIMER drops below 0.4V for the 32nd time), the LTC7003 retries, pull- ing TGUP to BST and turning on the external MOSFET. The FAULT pin will then go to a high impedance state. The total cooldown timer period is given by: TCOOL_DOWN = 63 • 1.0V • CTIMER 2.5µA The retry duty cycle in percent is to a first order indepen- dent of CT and is defined by: D = 100 • TOVER_CURRENT TOVER_CURRENT + TCOOL_DOWN To defeat the automatic retry, place a 100kΩ resistor in parallel with the TIMER capacitor. Note that the time to turn off from an overcurrent fault will be increased by 7% and the FAULT pin will remain low indicating a fault has occurred. To get the LTC7003 to retry and to clear the fault flag the INP signal needs to cycle low then back high. Typical turn-off times and cooldown periods for some standard value timer capacitors are shown Table 1: Table 1. Fault Time for Typical Capacitors CTIMER (nF) TOVER_CURRENT (µs) TCOOL_DOWN (s) Retry Duty Cycle % <0.1 1.4 0.0005 0.28 1 14 0.025 0.06 10 140 0.250 0.06 100 1400 2.500 0.06 COOLDOWN PERIOD (TCOOL_DOWN) 7003 F05 TIMER ∆VSNS V(TG-TS) (TGUP SHORTED TO TGDN) FAULT >30mV <30mV 0.4V 1ST 2ND 31ST 32ND INP 1.30V 1.40V Figure 5. Auto Retry Cool-Down Timer Cycle |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |