| поискавой системы для электроныых деталей |
|
MP171 датащи(PDF) 9 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP171 датащи(HTML) 9 Page - Monolithic Power Systems |
|
9 / 20 page ![]() MP171 –NON-ISOLATED OFFLINE REGULATOR MP171 Rev. 1.0 www.MonolithicPower.com 9 9/30/2015 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2015 MPS. All Rights Reserved. OPERATION MP171 is a green-mode-operation regulator: The peak current and the switching frequency both decrease with a decreasing load. As a result, it offers excellent light-load efficiency and improves overall average efficiency. Also, the regulator incorporates multiple features and operates with a minimal number of external components. The MP171 acts as a fully integrated regulator when used in buck topology (see Typical Application on page 1). Start-Up and Under-Voltage Lockout The internal high-voltage regulator self-supplies the IC from DRAIN. When VCC voltage reaches VCCOFF, the IC starts switching, and the internal high-voltage regulator turns off. The internal high- voltage regulator turns on to charge the external VCC capacitor when the VCC voltage falls below VCCON. A small capacitor (in the low μF range) maintains the VCC voltage and thus lowers the capacitor cost. The IC stops switching when the VCC voltage drops blow VCCstop. Under fault conditions—such as OLP, SCP, and TSD—the IC stops switching, and an internal current source (~16 μA) discharges the VCC capacitor. The internal high-voltage regulator will not charge the VCC capacitor until the VCC voltage drops below VCCpro. The re-start time can be estimated using Equation (1): pro OFF pro restart VCC CCLATCH regulator VCC VCC VCC VCC C II (1) Soft Start (SS) The IC stops operation when the VCC voltage drops below VCCstop; the IC begins operation when VCC charges to VCCOFF. Every time the chip starts operation there is a soft-start period. The soft start prevents the inductor current from overshooting by limiting the minimum off time. MP171 adopts a 2 phase minimum off time limit soft start. Each soft-start phase retains 128 switching cycles. During the soft start, the off time limit gradually shortens from 48 μs to 18 μs and finally reaches the normal operation off time limit (see Figure 2). 128 Switching cycle 48us 18 us 10us Driver 128 Switching cycle Figure 2— min off at start-up Constant Voltage (CV) Operation The MP171 regulates the output voltage by monitoring the sampling capacitor. At the beginning of each cycle, the integrated MOSFET turns on while the feedback voltage drops below the 2.55 V reference voltage, which indicates insufficient output voltage. The peak current limitation determines the on period. After the on period elapses, the integrated MOSFET turns off. The sampling capacitor (C3) voltage is charged to the output voltage when the freewheeling diode (D1) turns on. In his way, the sampling capacitor (C3) samples and holds the output voltage for output regulation. The sampling capacitor (C3) voltage decreases when the L1 inductor current falls below the output current. When the feedback voltage falls below the 2.55 V reference voltage, a new switching cycle begins. Figure 3 shows this operation in continuous conduction mode (CCM). MOSFET Diode I L Ipeak Io Vo VFB 2.55V Figure 3—VFB vs. VO Equation (2) determines the output voltage: R1 R2 Vo 2.55V R2 (2) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |