| поискавой системы для электроныых деталей |
|
MP2276GD датащи(PDF) 15 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MP2276GD датащи(HTML) 15 Page - Monolithic Power Systems |
|
15 / 23 page ![]() MP2276 – 16V, 8A, HIGH EFFICIENCY, SYNC, STEP-DOWN CONVERTER MP2276 Rev.1.0 www.MonolithicPower.com 15 3/22/2017 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2017 MPS. All Rights Reserved. Figure 4 shows pulse-skip mode operation at light-load condition. When FB drops below the superimposed COMP, the HS-FET turns on for a fixed interval. When the HS-FET turns off, the LS-FET turns on until the inductor current reaches zero. In pulse-skip mode operation, FB does not reach the superimposed COMP when the inductor current approaches zero. The LS- FET driver turns into tri-state (Hi-Z) when the inductor current reaches zero. Therefore, the output capacitors discharge slowly to PGND through the FB resistors (R1 and R2). At light- load condition, the HS-FET is not turned on as frequently in pulse-skip mode as it is in forced CCM. As a result, the efficiency in pulse-skip mode is improved greatly compared to that in forced CCM operation. PWM REF RAMP FB COMP TON HS-FET Driver LS-FET Driver IL IO Figure 4: Pulse Skip in Light Load As the output current increases from the light- load condition, the time period the current modulator regulates in becomes shorter. The HS-FET is turned on more frequently, and the switching frequency increases accordingly. The output current reaches the critical level when the current modulator time is zero. The critical level of the output current is determined with Equation (1): IN SW OUT OUT IN OUT V F L 2 V ) V V ( I (1) Where FSW is the switching frequency. The MP2276 enters PWM mode once the output current exceeds the critical level. Afterward, the switching frequency remains fairly constant over the output current range. The MP2276 can be configured to operate in forced CCM even in light-load condition (see Table 1). FREQ/MODE Selection The MP2276 provides both forced CCM operation and pulse-skip operation in light-load condition. The MP2276 has three options for switching frequency selection: 600kHz, 1100kHz, and 2000kHz. Select the operation mode under light-load condition and the switching frequency by choosing the resistance value of the resistor connected between MODE and AGND or VCC (see Table 1). Table 1: FREQ/MODE Selection MODE Light-Load Mode Switching Frequency AGND Forced CCM 1100kHz 30.1kΩ (±20%) to AGND Forced CCM 2000kHz 60.4kΩ (±20%) to AGND Forced CCM 600kHz 121kΩ (±20%) to AGND Pulse Skip 600kHz 243kΩ (±20%) to AGND Pulse Skip 2000kHz VCC Pulse Skip 1100kHz Soft Start (SS) The minimum soft-start time is limited to 1.7ms. This can be increased by choosing the capacitor between SS/TRK and AGND. A minimum value of 3.3nF for this capacitor is always required to stabilize the reference voltage. The capacitance of this capacitor can be determined with Equation (2) and Equation (3): 22 3 . 3 ) ( nF C SS (tSS = 1.7ms) (2) V A x ms t nF C ss SS 8 . 0 10 ) ( ) ( (tSS > 1.7ms) (3) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |