поискавой системы для электроныых деталей
  Russian  ▼
ALLDATASHEETRU.COM

X  

LVW5SN датащи(PDF) 17 Page - OSRAM GmbH

номер детали LVW5SN
подробное описание детали  white SMD package, colorless clear silicone
PDF  18 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  OSRAM [OSRAM GmbH]
домашняя страница  http://www.osram.com
Logo OSRAM - OSRAM GmbH

LVW5SN датащи(HTML) 17 Page - OSRAM GmbH

Back Button LVW5SN Datasheet HTML 10Page - OSRAM GmbH LVW5SN Datasheet HTML 11Page - OSRAM GmbH LVW5SN Datasheet HTML 12Page - OSRAM GmbH LVW5SN Datasheet HTML 13Page - OSRAM GmbH LVW5SN Datasheet HTML 14Page - OSRAM GmbH LVW5SN Datasheet HTML 15Page - OSRAM GmbH LVW5SN Datasheet HTML 16Page - OSRAM GmbH LVW5SN Datasheet HTML 17Page - OSRAM GmbH LVW5SN Datasheet HTML 18Page - OSRAM GmbH  
Zoom Inzoom in Zoom Outzoom out
 17 / 18 page
background image
LV W5SN
2010-09-08
17
Wegen der Streichung der LED aus der IEC 60825 erfolgt die Bewertung der Augesicherheit nach dem Standard IEC
62471:2006 ("photobiological safety of lamps and lamp systems").
Im Risikogruppensystem dieser CIE- Norm erfüllen die in diesem Datenblatt angegebenen LED die "moderate risk"- Grup-
pe (die die sich im "sichtbaren" Spektralbereich auf eine Expositionsdauer von 0,25 s bezieht). Unter realen Umständen
(für Expositionsdauer, Augenpupille, Betrachtungsabstand) geht damit von diesen Bauelementen keinerlei Augengefähr-
dung aus.
Grundsätzlich sollte jedoch erwähnt werden, dass intensive Lichtquellen durch ihre Blendwirkung ein hohes sekundäres
Gefahrenpotenzial besitzen. Wie nach dem Blick in andere helle Lichtquellen (z.B. Autoscheinwerfer) auch, können tem-
porär eingeschränktes Sehvermögen und Nachbilder je nach Situation zu Irritationen, Belästigungen, Beeinträchtigungen
oder sogar Unfällen führen.
Due to the cancellation of the LED from IEC 60825 the evaluation of eye safety occurs according to the standard IEC
62471:2006 ("photobiological safety of lamps and lamp systems").
Within the risk grouping system of this CIE standard, the LEDs specified in this data sheet fall into the "moderate risk" group
(relating to devices in the visible spectrum with an exposure time of 0.25s). Under real circumstances (for exposure time,
eye pupils, observation distance), it is assumed that no endangerment to the eye exists from these devices.
As a matter of principle, however, it should be mentioned that intense light sources have a high secondary exposure
potential due to their blinding effect. As is also true when viewing other bright light sources (e.g. headlights), temporary
reduction in visual acuity and afterimages can occur, leading to irritation, annoyance, visual impairment, and even
accidents, depending on the situation.
Attention please!
The information describes the type of component and shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved. Due to technical requirements components may contain
dangerous substances. For information on the types in question please contact our Sales Organization.
If printed or downloaded, please find the latest version in the Internet.
Packing
Please use the recycling operators known to you. We can also help you – get in touch with your nearest sales office.
By agreement we will take packing material back, if it is sorted. You must bear the costs of transport. For packing
material that is returned to us unsorted or which we are not obliged to accept, we shall have to invoice you for any costs
incurred.
Components used in life-support devices or systems must be expressly authorized for such purpose! Critical
components
8) page 18 may only be used in life-support devices or systems9) page 18 with the express written approval of
OSRAM OS.
Revision History: 2010-09-08
Previous Version:
2010-05-17
Page
Subjects (major changes since last revision)
Date of change
all
datasheet released
2008-11-26
4
R
th JS (typ.) added
2009-02-03
all
data sheet reworked
2009-12-16
1, 3, 4,
10
OS-PCN-2009-034-A
2009-12-16
all
data sheet reworked
2010-01-21
1, 11
additional information
2010-02-25
8 - 9
diagrams updated
2010-03-23
11
Package Outlines updated
2010-03-23
2, 6
ordering code changed
2010-05-17
all
datasheet reworked / diagrams page 8 corrected / eye safety information
page 17 updated
2010-09-08



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com