| поискавой системы для электроныых деталей |
|
MMW датащи(PDF) 7 Page - Wall Industries,Inc. |
|
|
|||||||||||||||||||||||||||||
MMW датащи(HTML) 7 Page - Wall Industries,Inc. |
|
7 / 8 page ![]() Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 11/14/2011 603-778-2300 www.wallindustries.com Fax 603-778-9797 Page 7 of 8 MMW Series Single and Dual Output 4:1 Input Voltage Range 25~30 Watt DC/DC Converter Rev C TEST CONFIGURATIONS Input Reflected-Ripple Current Test Setup Input reflected-ripple current is measured with an inductor Lin (4.7μH) and Cin (220μF, ESR < 1.0Ω at 100KHz) to simulate source impedance. Capacitor Cin offsets possible battery impedance. Current ripple is measured at the input terminals of the module. Measurement bandwidth is 0 ~ 500KHz. +Out -Out +Vin -Vin DC / DC Converter Load Battery + Lin + Cin To Oscilloscope Current Probe Peak-to-Peak Output Noise Measurement Test Use a Cout 1.0μF ceramic capacitor. Scope measurement should be made by using a BNC socket; measurement bandwidth is 0 ~ 20MHz. Position the load between 50mm and 75mm from the DC/DC Converter. +Out -Out +Vin -Vin Single Output DC / DC Converter Resistive Load Scope Copper Strip Cout +Out -Out +Vin -Vin Dual Output DC / DC Converter Resistive Load Scope Copper Strip Cout Com. Scope Cout Output Ripple Reduction A good quality low ESR capacitor placed as close as possible across the load will give the best ripple and noise performance. To reduce output ripple, it is recommended to use 4.7μF capacitors at the output. +Out -Out +Vin -Vin Load DC Power Source + - Cout Single Output DC / DC Converter +Out -Out +Vin -Vin Load DC Power Source + - Cout Com. Dual Output DC / DC Converter Thermal Considerations Many conditions affect the thermal performance of the power module, such as orientation, airflow over the module, and board spacing. To avoid exceeding the maximum temperature rating of the components inside the power module, the case temperature must be kept below 105°C. The derating curves are determined from measurements obtained in an experimental apparatus. DUT Position of air velocity probe and thermocouple 50mm / 2in Air Flow 15mm / 0.6in |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |