| поискавой системы для электроныых деталей |
|
CMMM датащи(PDF) 5 Page - Wall Industries,Inc. |
|
|
|||||||||||||||||||||||||||||
CMMM датащи(HTML) 5 Page - Wall Industries,Inc. |
|
5 / 7 page ![]() Wall Industries, Inc. 5 Watson Brook Road Exeter, NH 03833 603-778-2300 www.wallindustries.com Fax 603-778-9797 CMMM Series 2:1 Input Voltage Ranges 18~30 Watt, Single Output Chassis Mount DC/DC Converter Rev A Remote On/Off Positive logic remote on/off turns the module on during a logic high voltage on the remote on/off pin, and turns the module off during a logic low. To turn the power module on and off, the user must supply a switch to control the voltage between the on/off terminal and the -Vin terminal. The switch can be an open collector or equivalent. A logic low is -1V to 1.0V. A logic high is 2.5V to 100V. The maximum sink current at the on/off terminal (pin 4) during a logic low is - 100μA. The maximum allowable leakage current of the switch at the on/off terminal (pin 4) during a logic high (2.5 to 100V) is 5μA. Output Voltage Trim Output voltage trim allows the user to increase or decrease the output voltage set point of a module. The output voltage can be adjusted by placing an external resistor (R) between the Trim and +Vout or –Vout terminals. By adjusting R, the output voltage can be changed by ±10% of the nominal output voltage. +Out -Out +Vin -Vin Trim Up Enable Trim Trim Down 10K Trim Up/Down A 10K, 1 or 10 turn trimpot is usually specified for continuous trimming. Trim pin may be safely left floating if it is not being used. Connecting the external resistor (Rup) between the Trim and –Vout pins increases the output voltage to set the point as defined in the following equation: Rup = (33 x Vout) - (30 x Vadj) Vadj - Vout Connecting the external resistor (Rdown) between the Trim and +Vout pins decreases the output voltage set point as defined in the following equation: Rdown = (36.667 x Vadj) - (33 x Vout) Vout - Vadj Vout: Nominal Output Voltage Vadj: Adjusted Output Voltage Units VDC / K Ω Over Current Protection To provide protection in a fault (output overload) condition, the unit is equipped with internal current limiting circuitry and can endure current limiting for an unlimited duration. At the point of current-limit inception, the unit shifts from voltage control to current control. The unit operates normally once the output current is brought back into its specified range. Over Voltage Protection The output over voltage clamp consists of control circuitry that is dependent on the primary regulation loop that monitors the voltage on the output terminals. The control loop of the clamp has a higher voltage set point than the primary loop. This provides a redundant voltage control that reduces the risk of an output over voltage. The OVP level can be found in the protection specifications. Input Source Impedance |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |