| поискавой системы для электроныых деталей |
|
VDP3116B датащи(PDF) 21 Page - Micronas |
|
|
|||||||||||||||||||||||||||||
VDP3116B датащи(HTML) 21 Page - Micronas |
|
21 / 72 page ![]() PRELIMINARY DATA SHEET VDP 31xxB 21 Micronas 2.9. Analog Back End The digital RGB signals are converted to analog RGBs using three video digital to analog converters (DAC) with 10-bit resolution. An analog brightness value is provided by three additional DACs. The adjustment range is 40% of the full RGB range. Controlling the whitedrive/analog brightness and also the external contrast and brightness adjustments is done via the Fast Processor, located in the front-end. Control of the cutoff DACs is via I2C-bus registers. Finally cutoff and blanking values are added to the RGB signals. Cutoff (dark current) is provided by three 9-bit DACs. The adjustment range is 60% of full scale RGB range. The analog RGB-outputs are current outputs with cur- rent-sink characteristics. The maximum current drawn by the output stage is obtained with peak white RGB. An external half contrast signal can be used to reduce the output current of the RGB outputs to 50%. 2.9.1. CRT Measurement and Control The display processor is equipped with an 8-bit PDM- ADC for all measuring purposes. The ADC is connected to the sense input pin, the input range is 0 to 1.5V. The bandwidth of the PDM filter can be selected; it is 40/80 kHz for small/large bandwidth setting. The input impedance is more than 1 M Ω. Cutoff and white drive current measurement are carried out during the vertical blanking interval. They always use the small bandwidth setting. The current range for the cutoff measurement is set by connecting a sense resis- tor to the MADC input. For the whitedrive measurement, the range is set by using another sense resistor and the range select switch 2 output pin (RSW2). During the ac- tive picture, the minimum and maximum beam current is measured. The measurement range can be set by us- ing the range select switch 1 pin (RSW1) as shown in Fig. 2–21 and Fig. 2–22. The timing window of this mea- surement is programmable. The intention is to automati- cally detect letterbox transmission or to measure the ac- tual beam current. All control loops are closed via the external control microprocessor. SENSE RSW1 RSW2 R2 R3 beam current A D MADC R1 Fig. 2–21: MADC Range Switches ultra black black cutoff white drive CR + IBRM CR + IBRM + WDRV·WDR R G B TML CG + IBRM CB + IBRM PICTURE MEAS. PICTURE MEAS. TUBE MEASUREMENT active measurement resistor R1 øR2øR3 RSW1=on, RSW2=on R1 R1 øR3 RSW2 R R cutoff cutoff G B R1 øR2øR3 Fig. 2–22: MADC Measurement Timing RSW1=on, RSW2=on PMST PMSO =on Lines |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |