39 / 80 page ![]() Data Sheet ADAS1000/ADAS1000-1/ADAS1000-2 filtered, and synchronously demodulated in the digital domain; the result is a digital signal that represents the total thoracic or respiration impedance, including cable and electrode contri- butions. While it is heavily low-pass filtered on-chip, the user is required to further process it to extract the envelope and perform the peak detection needed to establish breathing (or lack thereof). Respiration measurement is available on one of the leads (Lead I, Lead II, or Lead III) or on an external path via a pair of dedicated pins (EXT_RESP_LA, EXT_RESP_RA, or EXT_RESP_LL). Only one lead measurement can be made at one time. The respiration measurement path is not suited for use as additional ECG measurements because the internal configuration and demodulation do not align with an ECG measurement; however, the EXT_RESP_LA, EXT_RESP_RA, or EXT_RESP_LL paths can be multiplexed into one of the ECG ADC paths, if required, as discussed in the Extend Switch On Respiration Paths section. The respiration signal processing path is not reconfigurable for ECG measurements, as it is specifically designed for the respiration signal measurement. Table 12. Maximum Allowable Cable and Thoracic Loading Cable Resistance Cable Capacitance R < 1 kΩ C < 1200 pF 1 kΩ < R < 2.5 kΩ C < 400 pF 2.5 kΩ < R < 5 kΩ C < 200 pF RTHORACIC < 2 kΩ Internal Respiration Capacitors The internal respiration function uses an internal RC network (5 kΩ/100 pF), and this circuit is capable of 200 mΩ resolution (with up to 5 kΩ total path and cable impedance). The current is ac-coupled onto the same pins that the measurement is sensed back on. Figure 69 shows the measurement on Lead I, but, similarly, the measurement can be configured to measure on either Lead II or Lead III. The internal capacitor mode requires no external capacitors and produces currents of ~64 µA p-p amplitude when configured for maximum amplitude setting (±1V) through the RESPCTRL register (see Table 30). External Respiration Path The EXT_RESP_xx pins are provided for use either with the ECG electrode cables or, alternatively, with a dedicated external sensor independent of the ECG electrode path. Additionally, the EXT_RESP_xx pins are provided so the user can measure the respiration signal at the patient side of any input filtering on the front end. In this case, the user must continue to take precautions to protect the EXT_RESP_xx pins from any signals applied that are in excess of the operating voltage range (for example, ESIS or defibrillator signals). Figure 69. Simplified Respiration Block Diagram LA CABLE ECG1_LA EXT_RESP_LA ECG2_LL EXT_RESP_LL ECG3_RA EXT_RESP_RA ADAS1000 OVERSAMPLED 5kΩ 5kΩ 100pF 100pF RESPIRATION DAC DRIVE + ±1V ±1V CABLE AND ELECTRODE IMPEDANCE < 5kΩ LL CABLE RA CABLE FILTER FILTER FILTER RESPIRATION MEASURE RESPIRATION DAC DRIVE– HPF IN-AMP AND ANTI-ALIASING MAGNITUDE AND PHASE SAR ADC 46.5kHz TO 64kHz 46.5kHz TO 64kHz LPF fc=10kHz fc=150kHz 7Hz Rev. B | Page 39 of 80 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |