69 / 87 page ![]() 000-0046170-103 Page 68 of 86 SLG46170 17.0 Power On Reset (POR) 17.1 POR Overview The Power On Reset (POR) Macrocell will produce a high or “1” signal as an output when the device power supply (VDD) rises to approximately 1.4 V. The typical internal delay for POR to release POR_IO will be 1 ms + depending on the power slope, because there is adaptive power-up sequence. The next internal signal will be POR_CORE and then POR_IO_DLY, each of which is further delayed by approximately 1 µs. The rise of POR_IO_DLY will trigger the I/O pins to exit tri-state, and the device will become active. 17.2 POR Timing Diagram Figure 38. POR Timing Diagram VDD POR IO POR CORE POR_IO_DLY RST 1.4 V 1 ms + 1 s 1 s Output PAD Determined by function logic Tri-state Initial state determined by registers s[1:0] |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|