General Description:
The single and dual channel DIN Rail Temperature Signal Converter D1072S and
D1072D accepts a low level dc signal from millivolt, thermocouple or RTD temperature
sensor, located in Hazardous Area, and converts, with isolation, the signal to drive a
Safe Area load. Output signal can be direct or reverse.
Duplicator function provides two independent outputs for the single input.
Adder, subtractor, low/high selector functions provides two independent outputs
representing input A, input B, input A plus input B, input A minus input B,
low/high selector.
Features:
SIL 2 according to IEC 61508:2010 (Route 2H)
for analog current source output of each channel
D1072S:Tproof = 3/10 yrs (≤10% / >10 % of total SIF)
D1072D:Tproof = 3/10 yrs (≤10% / >10 % of total SIF)
SC2 : Systematic Capability SIL2.
Input from Zone 0 (Zone 20), Division 1,
installation in Zone 2, Division 2.
mV, thermocouples, RTD or
transmitting potentiometers Input Signal.
Programmable RTD line resistance compensation.
Reference Junction Compensation automatic or
fixed (programmable value).
0/4-20 mA, 0/1-5 V, 0/2-10 V
Output Signal temperature linear or reverse.
Duplicated output for single channel input.
Adder, Subtractor, low/high Selector.
16 characters tag for each channel.
Common burnout detection available when
using Power Bus enclosure.
High Accuracy, μP controlled A/D converter.
Three port isolation, Input/Output/Supply.
EMC Compatibility to EN61000-6-2, EN61000-6-4.
Fully programmable operating parameters.
ATEX, IECEx, UL & C-UL, FM & FM-C, INMETRO, EAC-EX,
UKR TR n. 898, TÜV Certifications.
TÜV Functional Safety Certification.
Type Approval Certificate DNV and KR for
maritime applications.
High Reliability, SMD components.
High Density, two channels per unit.
Simplified installation using standard
DIN Rail and plug-in terminal blocks.
250 Vrms (Um) max. voltage allowed to the
instruments associated with the barrier.
|