## Overview of XCSDMP79110
The **XCSDMP79110** is a coded magnetic safety switch manufactured by **Telemecanique Sensors** (part of the Schneider Electric ecosystem). It is primarily used in industrial safety applications to monitor the status of movable guards, gates, and covers.
### 1. Key Technical Specifications
| Feature | Specification |
| :--- | :--- |
| **Product Type** | Coded Magnetic Safety Switch |
| **Contact Configuration** | 2 NC (Normally Closed) + 1 NO (Normally Open) |
| **Housing Material** | Rectangular Plastic (Compact) |
| **Cable Length** | 10 Meters (Standard) |
| **Operating Voltage** | 24V DC |
| **Switching Distance** | Sao: 8 mm (Assured operating distance) |
| **Breaking Distance** | Sar: 20 mm (Assured release distance) |
| **Protection Rating** | IP66 / IP67 (Water and Dust Resistant) |
---
### 2. Electronic Components & Internal Logic
The "Electronic" nature of this device differs from a standard mechanical limit switch. Because it is a **coded magnetic** device, it relies on specific magnetic fields to trigger the internal solid-state or reed-based components.
#### A. Coded Magnetic Actuation
Unlike a simple magnet that can be tricked by a piece of steel or a generic magnet, the XCSDMP79110 requires a specific **coded actuator** (usually the XCSZP1). The internal electronic sensors are arranged to detect a specific polar pattern, preventing "defeat" or tampering by unauthorized magnets.
#### B. The Contact Configuration (2NC + 1NO)
This part number features a three-contact arrangement:
* **2 NC (Safety Contacts):** These are used in the safety circuit. When the guard is closed, these contacts are held closed. If the guard opens, the circuit breaks, triggering the Safety Relay.
* **1 NO (Signaling/Auxiliary):** This is typically used for PLC input or an HMI light to indicate the status of the door without affecting the safety category of the machine.
#### C. Pre-wired Connection
The "10" at the end of the part number indicates a **10-meter pre-wired cable**. The internal wires are color-coded to allow for easy integration into a safety control module (like the Preventa XPS range).
---
### 3. Application and Safety Standards
The electronic design of the XCSDMP79110 allows it to reach high safety levels when used with a monitoring relay:
1. **Safety Category:** Up to Category 4 (with appropriate monitoring).
2. **Performance Level:** Can reach **PL e** (ISO 13849-1).
3. **Silent Operation:** Since there are no mechanical levers, the electronic switching is silent and resistant to physical wear.
4. **Hygienic Design:** The plastic housing is easy to clean, making it suitable for food processing or pharmaceutical machinery where electronic components must be sealed.
---
### 4. Wiring Diagram (Conceptual)
```yaml
Wire Color (Standard) | Function
---------------------|----------------------
Brown / Blue | Contact 1 (NC)
Black / White | Contact 2 (NC)
Red / Grey | Contact 3 (NO) - Signaling
```
*Note: Always verify specific wire colors against the datasheet provided with the specific batch, as wiring standards can vary by region.*
- ⤷