AI

The **W2AP-A34-R2/UL** is a high-performance, industrial-grade AC axial fan manufactured by **NMB Technologies (MinebeaMitsumi)**. It is designed for thermal management in heavy-duty environments, such as server racks, industrial control panels, and power supplies.
---
### ## Technical Specifications
| Parameter | Specification |
| :--- | :--- |
| **Input Voltage** | 115 VAC (Standard Utility Power) |
| **Frequency** | 50 / 60 Hz |
| **Airflow** | ~91.8 CFM (Cubic Feet per Minute) |
| **Speed** | 2,700 - 3,100 RPM |
| **Noise Level** | ~40 - 44 dB |
| **Power Consumption** | ~14 - 15 Watts |
| **Bearing Type** | Dual Ball Bearing |
| **Termination** | Lead Wires (2-wire) |
| **Certifications** | UL Listed, CSA, CE, RoHS |
---
### ## Key Electronic & Mechanical Components
### 1. Motor Design
The unit utilizes a **Shaded Pole Induction Motor**. This is common in AC fans because it is electronically simple, highly reliable, and does not require a start capacitor, reducing the risk of component failure over time.
### 2. Dual Ball Bearing System
Unlike cheaper "sleeve bearing" fans, the **R2** designation typically refers to the high-quality **Dual Ball Bearing** construction.
* **Advantage:** Supports much higher operating temperatures (up to 70°C).
* **Longevity:** Rated for a significantly longer "Mean Time To Failure" (MTTF), often exceeding 50,000 to 100,000 hours.
### 3. Housing and Impeller
* **Frame:** Cast Aluminum. This acts as a heat sink for the motor itself and provides structural rigidity to prevent vibration.
* **Impeller:** Reinforced Polycarbonate (Plastic) or Metal (depending on the specific sub-variant), designed with an aerodynamic profile to maximize static pressure.
### 4. Thermal Protection
The "UL" suffix indicates that the motor is **Impedance Protected**. This means that if the fan blades are physically obstructed (locked rotor), the internal resistance of the motor windings prevents the current from rising to a level that would cause a fire or melt the insulation.
---
### ## Wiring Diagram (Standard AC)
Since this is a standard AC component, the wiring is straightforward:
```text
[ Power Source 115V ]
|
+---- (Black Wire) ----> [ Fan Motor ]
|
+---- (Black Wire) ----> [ Fan Motor ]
```
*(Note: In AC shaded-pole fans, polarity is generally not a concern for operation, though grounding the metal frame to the chassis is recommended for safety.)*
---
- ⤷
What is the difference between this 115V model and the 230V version?
- ⤷ How do I calculate the static pressure requirements for this fan in an enclosure?
- ⤷ Can this fan be used with a speed controller or dimmer?