SES-2HB-R/E
AI

The **SES-2HB-R/E** is a specific model of an **Electromagnetic Holder (Door Release)** typically used in fire safety and security systems. It is designed to hold fire doors open during normal operation and release them automatically when a fire alarm is triggered.
---
### 1. Technical Specifications
The following table outlines the primary electronic and physical characteristics of the device:
| Feature | Specification |
| :--- | :--- |
| **Operating Voltage** | 24V DC (Standard for Fire Systems) |
| **Current Consumption** | Approximately 60mA - 100mA |
| **Holding Force** | ~200N to 500N (Varies by specific sub-model) |
| **Material** | Steel/Zinc alloy housing |
| **Mounting Type** | Wall or Floor mounted (depending on bracket) |
| **Release Mechanism** | Power-off to release (Fail-safe) |
---
### 2. Key Electronic Components
The device operates on simple yet robust electromagnetic principles:
* **Electromagnetic Coil:** The core component consists of a copper wire coil. when 24V DC is applied, it generates a magnetic field that attracts the metal armature plate attached to the door.
* **Armature Plate:** A passive metal plate that completes the magnetic circuit. It usually features a "swivel" or "pivoting" joint to ensure it sits flush against the magnet even if the door is slightly misaligned.
* **Protection Diode (Flyback Diode):** Most units include an internal diode across the coil to prevent inductive voltage spikes from damaging the fire alarm control panel (FACP) when the power is cut.
* **Manual Release Button:** A physical override button located on the housing that breaks the electrical circuit locally to test the door manually.
---
### 3. Operational Logic
The SES-2HB-R/E follows a **Fail-Safe** logic, which is critical for life safety:
1. **Normal Condition:** The Fire Alarm Panel provides a constant 24V DC supply. The magnet is energized, holding the door open to allow traffic flow.
2. **Alarm Condition:** The Fire Alarm Panel detects smoke/fire and cuts the power to the 24V circuit.
3. **Release:** The magnetic field collapses instantly, and the door closer (mechanical arm) pulls the door shut to prevent the spread of smoke.
---
### 4. Installation Wiring Diagram
*Note: Always refer to the manufacturer's specific schematic before wiring.*
```text
[ Fire Alarm Control Panel ]
|
|----(+) 24V DC ----[ Terminal L1 ]
| |
|----(-) 0V/GND ----[ Terminal L2 ]
```
---
- ⤷
What is the maximum holding force for the SES-2HB series?
- ⤷ How do I wire a manual override switch to this electromagnetic holder?
- ⤷ What are the common maintenance steps for fire door magnets?