OBE2000-R3-SE2
AI

The **OBE2000-R3-SE2** is a high-performance miniature thru-beam photoelectric sensor manufactured by Pepperl+Fuchs. It is designed for industrial automation where space is limited but high reliability is required.
---
### 1. Core Technical Specifications
The following table highlights the primary electronic and operational characteristics of the device:
| Feature | Specification |
| :--- | :--- |
| **Detection Method** | Thru-beam (Emitter/Receiver pair) |
| **Detection Range** | 0 to 2000 mm (2 meters) |
| **Operating Voltage** | 10 ... 30 V DC |
| **Output Type** | PNP, Open Collector, Short-circuit protected |
| **Switching Type** | Dark-ON (Output active when light beam is interrupted) |
| **Switching Frequency** | approx. 1000 Hz (1 ms response time) |
| **Current Consumption** | < 15 mA |
---
### 2. Electronic Component Breakdown
#### A. The Emitter and Receiver Logic
As a **thru-beam sensor**, the system consists of two separate components:
* **Emitter:** Uses a high-intensity **Visible Red LED** (approx. 630 nm). The red light makes alignment much easier for technicians during installation.
* **Receiver:** Contains the phototransistor and processing circuitry to detect the presence or absence of the emitted light.
#### B. Output Circuitry (PNP / Dark-ON)
The "SE2" suffix indicates the output configuration:
* **PNP Output:** When the sensor is triggered, it connects the output pin to the positive supply voltage (V+).
* **Dark-ON (D-ON):** The output signal is high when the light beam is **interrupted** (i.e., an object is present between the emitter and receiver).
#### C. Connectivity and Housing
* **Wiring:** Usually equipped with a fixed cable or a M8 plug connection (depending on the specific sub-model).
* **Protection:** Integrated protection against reverse polarity and short circuits ensures the internal electronics are not damaged by wiring errors.
* **Environmental Rating:** IP67 rated, meaning the internal electronics are fully sealed against dust and immersion in water.
---
### 3. Connection Diagram (Standard Wire Colors)
The typical wiring for the receiver unit is as follows:
```markdown
1. Brown (L+) --> +10 to 30V DC
2. White (NC) --> Not Connected (usually)
3. Blue (L-) --> 0V / Ground
4. Black (OUT) --> Load / PLC Input (PNP Signal)
```
---
### 4. Key Applications
* **Small Parts Detection:** Due to its miniature R3 series housing.
* **Conveyor Monitoring:** Counting objects or detecting jams in narrow spaces.
* **Robotics:** End-of-arm tooling position sensing.
- ⤷
What is the difference between Light-ON and Dark-ON switching for this model?
- ⤷ Can the OBE2000-R3-SE2 be used with an NPN logic PLC?
- ⤷ How do I align the emitter and receiver for maximum range?