    ## FRS-R-100: Electronic and Mechanical Specifications The **FRS-R-100** is a high-performance, current-limiting time-delay fuse belonging to the **Fusetron™** series manufactured by Eaton (Bussmann Division). It is classified under the **UL Class RK5**. ### 1. Key Technical Specifications | Feature | Specification | | :--- | :--- | | **Current Rating** | 100 Amperes | | **Voltage Rating (AC)** | 600 Vac | | **Voltage Rating (DC)** | 300 Vdc | | **Interrupting Rating (AC)** | 200,000 Amps RMS Symmetrical | | **Interrupting Rating (DC)** | 20,000 Amps | | **Fuse Class** | Class RK5 | | **Response Time** | Time-Delay (Minimum 10s at 500% load) | --- ### 2. Electronic Composition and Features The FRS-R-100 is engineered with a **dual-element** construction, which allows it to distinguish between temporary power surges and actual dangerous faults. #### Dual-Element Design * **Thermal Element:** Handles low-level overloads. It consists of a spring-loaded mechanism triggered by a solder alloy that melts when specific heat levels are reached. This provides the "Time-Delay" characteristic, allowing motors to start without blowing the fuse. * **Magnetic/Instantaneous Element:** Handles high-level short circuits. This part reacts instantly to clear massive surges of electricity before they damage downstream components. #### Current Limitation Despite being a time-delay fuse, it is **current-limiting**. In the event of a major short circuit, it clears the fault so quickly that it prevents the current from reaching its full peak magnitude, protecting sensitive electronic equipment from magnetic and thermal stress. --- ### 3. Physical Dimensions (Cartridge Style) The 100A variant uses a standardized cylindrical body with blade-style connectors. * **Overall Length:** 7.88 inches (200.2 mm) * **Diameter:** 1.11 inches (28.2 mm) * **Body Material:** High-grade fiberglass tube for superior arc quenching and structural integrity. --- ### 4. Primary Applications The FRS-R-100 is typically used in industrial and commercial settings for: * **Motor Branch Circuits:** Its time-delay feature accommodates high inrush currents during motor startup. * **Transformer Protection:** Resists blowing during transient surges. * **Main Service Disconnects:** Provides high-capacity interrupting ratings for building mains.
    ✨ Follow-up Questions
    • ⤷ What is the difference between a Class RK5 and a Class RK1 fuse?
    • ⤷ Can the FRS-R-100 be used in 480V three-phase systems?
    • ⤷ How does the 'Rejection' feature in the R-series prevent incorrect installation?