Based on the technical specifications for fire alarm systems, the **FLM-C5-R** (specifically within the Bosch Security Systems ecosystem) refers to a **Conventional Zone Module** with an integrated relay.
Below is the detailed breakdown of its electronic components and functions.
---
## 1. Technical Overview
The FLM-C5-R is designed to interface conventional detectors (2-wire or 4-wire) into an addressable LSN (Local Security Network) loop. It allows older technology or specialized sensors to communicate with a modern digital fire panel.
### Core Specifications
| Parameter | Specification |
| :--- | :--- |
| **Input Voltage** | 15 V DC to 33 V DC (LSN loop) |
| **Current Consumption** | < 8.5 mA |
| **Line Resistance** | Max 50 $\Omega$ per zone |
| **Relay Contact Rating** | 2 A @ 30 V DC |
| **Environment Class** | IP 30 (NEMA 1 equivalent) |
---
## 2. Main Electronic Sub-Systems
### A. LSN Interface (Addressable Logic)
The "brain" of the module is the **LSN Controller IC**.
* **Function:** It manages bidirectional communication with the fire panel.
* **Addressing:** It typically features rotary switches or is programmed electronically to assign a unique ID on the loop.
* **Isolation:** Includes integrated **Short-Circuit Isolators** to ensure that a fault in one segment of the loop does not disable the entire system.
### B. Conventional Zone Input
This section acts as a bridge for non-addressable devices.
* **Monitoring:** It monitors the "End of Line" (EOL) resistor (usually 3.9 k$\Omega$).
* **State Detection:** It distinguishes between four electrical states:
1. **Standby:** Normal resistance detected.
2. **Alarm:** Low resistance (short) detected across the line.
3. **Fault:** Open circuit detected.
4. **Short Circuit:** Zero resistance detected.
### C. The Relay Output ("R" Designation)
The "R" in FLM-C5-R stands for **Relay**.
* **Hardware:** A physical electromechanical or solid-state relay.
* **Configuration:** Usually provides a Form C contact (Common, Normally Open, Normally Closed).
* **Use Case:** Triggers external hardware like fire doors, ventilation fans, or elevator recalls when the zone enters an alarm state.
---
## 3. Physical Connections & Wiring
The terminal block layout is critical for proper electronic installation:
```text
[ Terminals ] [ Description ]
LSN a1/b1 In <-- From Fire Panel Loop
LSN a2/b2 Out --> To next Device
ZONE + / - <-- Conventional Detectors
RELAY C/NO/NC --> External Control Circuit
```
---
## 4. Operational Features
* **Status Indicators:** Usually equipped with a red LED that flashes during communication and stays solid during an alarm event.
* **Reset Capability:** The module can interrupt power to the conventional zone to reset smoke detectors after an alarm is cleared at the panel.
---
- ⤷