CD16RM0S-K-R
AI

The **CD16RM0S-K-R** is a high-quality, miniature rotary coded switch manufactured by **C&K** (part of Littelfuse). These components are widely used in industrial and telecommunications equipment to set hardware addresses or configurations manually.
---
## 1. Technical Specifications
The following table summarizes the primary electrical and mechanical characteristics of the CD16RM0S-K-R:
| Feature | Specification |
| :--- | :--- |
| **Manufacturer** | C&K / Littelfuse |
| **Series** | CD Series |
| **Number of Positions** | 16 (Hexadecimal) |
| **Output Code** | Hexadecimal (0-9, A-F) |
| **Actuator Type** | Rotary for screwdriver (Flush) |
| **Mounting Type** | Surface Mount (SMT), Gull Wing |
| **Contact Rating** | 0.4 VA @ 20V AC/DC |
| **Operating Temperature** | -25°C to 85°C |
| **Process Sealed** | Yes (IP67 equivalent) |
---
## 2. Key Components & Construction
### A. The Actuator (K-R)
The "K" in the part number indicates a **Flush Actuator**. It requires a small flat-head screwdriver to turn. This design prevents accidental changes to the settings once the device is installed. The "R" stands for **Tape & Reel** packaging, suitable for automated pick-and-place assembly.
### B. Output Coding (Hexadecimal)
This is a 16-position switch. As you rotate the dial, internal metal contacts bridge specific output pins to a common pin (COM).
* **0-9:** Standard decimal digits.
* **A-F:** Representing values 10 through 15.
* This allows a single component to represent 4 bits of binary data ($2^4 = 16$).
### C. Sealing and Durability
The unit features an internal O-ring and is "process sealed." This means it can withstand **automated soldering** (reflow) and subsequent **aqueous cleaning** (washing) without liquid entering the internal contact mechanism.
---
## 3. Pin Configuration (Internal Logic)
The switch typically has a "Common" pin and four data pins (labeled 1, 2, 4, and 8). The output follows standard Binary Coded Decimal (BCD) logic:
| Position | Pin 1 (1) | Pin 2 (2) | Pin 3 (4) | Pin 4 (8) |
| :--- | :--- | :--- | :--- | :--- |
| **0** | Open | Open | Open | Open |
| **1** | Closed | Open | Open | Open |
| **7** | Closed | Closed | Closed | Open |
| **F (15)**| Closed | Closed | Closed | Closed |
---
## 4. Typical Applications
* **Address Setting:** Assigning a unique ID to a node on a bus (e.g., RS-485 or CAN bus).
* **Mode Selection:** Choosing between different firmware operating modes in an embedded system.
* **Industrial Controls:** Setting timer durations or limit thresholds on a PCB.
---
- ⤷
What is the difference between the 'RM' and 'RL' mounting styles in the CD series?
- ⤷ How should I handle the soldering temperature profile for this SMT component?
- ⤷ Are there 8-position (Octal) versions of this switch available?