8345-C04B-R0
AI

The **8345-C04B-R0** is a specific part number belonging to the **8345 series** of hydraulic-magnetic circuit breakers manufactured by **E-T-A**. This series is designed for high-performance applications, offering precision tripping and robust protection.
---
### ## Technical Specifications Overview
The 8345-C04B-R0 is a configurable magnetic circuit breaker. Below is a breakdown of its primary electronic and physical characteristics:
| Feature | Specification Details |
| :--- | :--- |
| **Series** | 8345 (Hydraulic-Magnetic) |
| **Number of Poles** | Multipolar (Variable based on configuration, typically 2 or 3) |
| **Mounting Style** | Rail mounting or Flange mounting |
| **Actuator Style** | Rocker switch / Toggle |
| **Voltage Rating** | Up to 80V DC or 240/415V AC (depends on sub-code) |
| **Current Rating** | Typically ranges from 0.05A to 125A |
| **Trip Mechanism** | Hydraulic-Magnetic (Temp independent) |
---
### ## Key Electronic Components & Operation
#### 1. Hydraulic-Magnetic Trip Mechanism
Unlike thermal breakers that rely on a bimetallic strip (which is sensitive to ambient temperature), the 8345-C04B-R0 uses a solenoid coil with a spring-loaded core submerged in silicone oil.
* **Precision:** It trips based on the actual current flow, not heat.
* **Consistency:** The trip point remains stable regardless of whether the equipment is in a cold server room or a hot industrial floor.
#### 2. The "C04B" Configuration Segment
In E-T-A nomenclature, these codes define the specific internal behaviors:
* **Characteristic (C):** Defines the delay curve (e.g., Short Delay, Medium Delay, or Long Delay). This allows for high inrush currents (like starting a motor) without nuisance tripping.
* **Terminal Design (04):** Refers to the physical connection points, often blade terminals or screw terminals.
* **Mounting/Actuator (B):** Denotes the rocker style or handle color/marking.
#### 3. Protection Features
* **Auxiliary Contacts:** These units often include a signal contact to notify a PLC or control system if the breaker has tripped.
* **Galvanic Isolation:** Provides physical separation of the circuit when in the "OFF" position for safety.
---
### ## Common Applications
The 8345 series is widely used in environments where reliability is critical:
1. **Telecommunications:** Protection of DC power distribution units (PDUs).
2. **Industrial Automation:** Safeguarding PLCs and sensitive control circuits.
3. **Marine/Transportation:** Due to its resistance to vibration and temperature fluctuations.
4. **Medical Equipment:** High precision current monitoring.
---
- ⤷