The **1490-RBU** is a specific electronic accessory manufactured by **Rockwell Automation (Allen-Bradley)**. It is categorized as a **Remote Reset Solenoid Unit**, primarily used in conjunction with industrial circuit breakers and thermal overload relays.
---
### 1. Function and Purpose
The 1490-RBU is designed to allow operators to reset a tripped device (like a 1490 Series Circuit Breaker) from a distance. In industrial control panels, safety protocols often require the enclosure to remain closed while the equipment is live; this solenoid allows for electronic resetting via a pushbutton on the cabinet door or through a PLC (Programmable Logic Controller) signal.
### 2. Technical Specifications
Below are the general characteristics typically associated with the 1490-RBU series:
| Feature | Specification |
| :--- | :--- |
| **Component Type** | Remote Reset Solenoid / Unit |
| **Compatibility** | Allen-Bradley 1490 series and specific Overload Relays |
| **Voltage Options** | Often available in 24V DC, 120V AC, or 240V AC (Check specific suffix) |
| **Duty Cycle** | Intermittent (designed for momentary activation) |
| **Mounting** | Direct attachment to the front or side of the protection device |
---
### 3. Key Electronic Components
The "parts" inside a 1490-RBU are relatively simple but robust for industrial environments:
* **Electromagnetic Coil:** The heart of the unit. When energized, it creates a magnetic field that pulls a mechanical plunger.
* **Plunger/Actuator:** A physical rod that moves when the coil is energized to strike the "Reset" button on the main circuit breaker.
* **Terminal Blocks:** Secure connection points for the control wiring (typically A1/A2 or similar labeling).
* **Housing:** High-impact, flame-retardant plastic designed to withstand high temperatures inside a control cabinet.
---
### 4. Application Example
1. **Fault Occurs:** A motor draws too much current, causing the 1490 circuit breaker to trip.
2. **Signal Sent:** An operator presses a "Reset" button on the HMI or control desk.
3. **Activation:** The 1490-RBU coil energizes, pushing the plunger.
4. **Recovery:** The circuit breaker is mechanically reset to the "On" or "Ready" position without the operator opening the high-voltage cabinet.
---
### 5. Installation Note
> [!WARNING]
> **Safety First:** Ensure all power is disconnected before installing or servicing a 1490-RBU. These units must be matched correctly to the control voltage of your system (e.g., do not apply 120V to a 24V DC rated solenoid).
- ⤷
What are the specific voltage suffixes for the 1490-RBU series?
- ⤷ Can the 1490-RBU be used for remote tripping as well as resetting?
- ⤷ Which specific Allen-Bradley circuit breaker series are compatible with this unit?