| поискавой системы для электроныых деталей |
|
P6002ACMC датащи(PDF) 149 Page - Teccor Electronics |
|
|
|||||||||||||||||||||||||||||
P6002ACMC датащи(HTML) 149 Page - Teccor Electronics |
|
149 / 212 page ![]() UL 497 © 2002 Teccor Electronics 4 - 25 http://www.teccor.com SIDACtor® Data Book and Design Guide +1 972-580-7777 Performance Tests Key performance tests which concern overvoltage protectors are detailed in the arrestor test section. Specific requirements are: • Breakdown Voltage Measurement — Arrestors are to be tested in the protector blocks or panels in which they are intended to be employed. Arrestors are required to break down within ±25% of the manufacturer’s specified breakdown rating. In no case shall the breakdown voltage exceed 750 V peak when subjected to the strike voltage test shown in Figure 4.8. At no time during this test will the supply voltage be increased at a rate greater than 2000 V/µs. • Impulse Spark-over Voltage Measurement — The arrestor must break down at less than 1000 V peak when subjected to a single impulse potential. Arrestors are to be tested in each polarity with a rate of voltage rise of 100 V/µs, ±10%. • Abnormal Operation — Single pair fuseless arrestors must be able to simultaneously carry 30 A rms at 480 V rms for 15 minutes without becoming a fire hazard. A fire hazard is determined by mounting the arrestor on a vertical soft wood surface and covering the unit with cheesecloth. Any charring or burning of the cheesecloth results in test failure. During this test, although the arrestors may short, they must not have an impulse spark- overvoltage or DC breakdown voltage greater than 1500 V peak. • Discharge Test — Protectors must comply with the strike voltage requirements after being subjected to five successive discharges from a 2 µF capacitor charged to 1000 V dc. (Figure 4.9). • Repeated Discharge Test — The arrestor must continue to break down at or below its maximum rated breakdown voltage after being subjected to 500 discharges from a 0.001 µF capacitor charged to a potential of 10,000 V dc. The interval between pulses is five seconds. Arrestors are to be tested in each polarity, and it is acceptable for the protector to short circuit following the discharge testing. (Figure 4.9) Figure 4.8 UL 497 Breakdown Voltage Measurement Test Specimen C1 R2 10 Ω 5 W R1 50,000 Ω 25 W Variable DC Supply 0-1000 V V |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |