129 / 212 page ![]() GR 1089–Core © 2002 Teccor Electronics 4 - 5 http://www.teccor.com SIDACtor® Data Book and Design Guide +1 972-580-7777 AC Power Fault Test is that the EUT may be damaged, but it may not become a fire, fragmentation, or electrical safety hazard. Passing criteria for the Current Limiter Test is that the EUT may be damaged but it may not exceed the acceptable time/current criteria (that is, cannot cause the wiring simulator as shown in Figure 4.2 to open) nor become a fire, fragmentation, or electrical safety hazard. The indicator used in measuring fire, fragmentation, and electrical safety hazards is a bleached, untreated cotton cheesecloth wrapped around the EUT. Compliance with testing is determined by the absence of ignition, charring, and the ejection of molten material or fragments. First Level Lightning Surge Test To pass the First Level Lightning Surge Test, the EUT must be undamaged and continue to operate properly after the stress is applied. This is referred to as passing “operationally.” Table 4.3 presents the conditions for the First Level inter-building criteria. Applicants have the option to submit their equipment to meet surges 1, 2, 4, and 5 or surges 3, 4, and 5. Table 4.4 presents the conditions for the intra-building criteria. Notes: 1. Primary protectors are removed for all tests. 2. For EUT containing secondary voltage limiting and current limiting protectors, tests are to be performed at the indicated voltage(s) and repeated at a reduced voltage and current just below the operating threshold of the secondary protectors. 3. Test 1 and 2 can be replaced with Test 3 or vice versa. 4. Alternatively, a surge generator of 1.2x50 µs open-circuit voltage waveform (8x20 µs short-circuit current waveform) per IEEE C62.41 may be used. The current shall be limited by the inclusion of a series 3 W resistor placed externally to the surge generator. 5. This test is to be performed on up to 12 Tip and Ring pairs simultaneously. Notes: • For EUT containing secondary voltage limiting and current limiting protectors, tests are to be performed at the indicated voltage(s) and repeated at a reduced voltage and current just below the operating threshold of the secondary protectors. • Alternatively, a surge generator of 1.2x50 µs open-circuit voltage waveform (8x20 µs short-circuit current waveform) per IEEE C62.41 may be used. The current shall be limited by the inclusion of a series 6 W resistor for Test 1 and a 12 W resistor for Test 2, placed externally to the surge generator. Table 4.3 First Level Lightning Surge Test Test (Notes 1 & 2) Surge Voltage (VPK) Waveform (µs) Surge Current per Conductor (A) Repetitions Each Polarity Test Connections (Table 4.1, Figure 4.1) 1 ±600 10x1000 100 25 A 2 (Note 3) ±1000 10x360 100 25 A 3 (Note 3) ±1000 10x1000 100 25 A 4 (Note 4) ±2500 2x10 500 10 B 5 (Note 5) ±1000 10x360 25 5 B Table 4.4 Intra-Building Lightning Surge Test Test Surge Voltage (VPK) Wave-form (µs) Surge Current per Conductor (A) Repetitions Each Polarity Test Connections (Table 4.1, Figure 4.1) 1 ±800 2x10 100 1 A1, A2 2 ±1500 2x10 100 1 B |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |