| поискавой системы для электроныых деталей |
|
PC87570 датащи(PDF) 166 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
PC87570 датащи(HTML) 166 Page - National Semiconductor (TI) |
|
166 / 168 page ![]() Bootloader Description 166 www.national.com If STRPST.SHBM = 1 (read Strap Register, Shared BIOS Memory bit) Set MCFG.SHMEM (Enable Shared BIOS Memory access) If KBC Header Signature not valid or KBC code size equal 0 Jump to KBC_Mem_Fail (bytes 0 & 1 = signature, byte 2 = size) If Checksum of KBC code not valid Jump to KBC_Mem_Fail If OEM_Detect_Crisis Address = FFFFh Jump to KBC code entry (OEM_Detect_Crisis Address is byte 4 in KBC Header, Start of KBC code is byte 2 of KBC Header) Else Jump to OEM_Detect_Crisis routine OEM_Detect_Crisis routine resides in external memory and must: 1. Save RA register on entry and use its contents as a return address 2. Preserve all configuration registers xxCFG 3. Preserve Boot Program variables in RAM F000h - F0010h 4. Return with Interrupts disabled: PFAIL.EN=0, PSR.I=0 5. Return with PSR.Z = 1 if NO crisis detected Note: It is OK for the OEM_Detect_Crisis routine to destroy stacks and interrupt dispatch table If PSR.Z = 1 Jump to KBC code entry (Start of KBC code is byte 2 of KBC Header) Else Jump to OEM_Mem_Fail (handle Crisis as if it were an external memory failure) Config_Mem_Fail (come here if Configuration Block Signature is not valid) Jump to EXT_Mem_Fail OEM_Mem_Fail Set OEM Failure Flag & Jump to EXT_Mem_Fail KBC_Mem_Fail Set KBC Failure Flag & Jump to EXT_Mem_Fail EXT_Mem_Fail Stacks & Dispatch table is restored (may have been modified by OEM_Detect_Crisis routine), Host Interface is turned on, registers are initialized and program goes into a loop awaiting system input on the host interface, port 64h (port 60h is read only because commands to the keyboard are not supported). Commands: 90h Load RAM Command 90h gets 4 byte of System Data: RAM address LOW, HIGH and Data array length LOW,HIGH and then receives and loads number of bytes specified by length into the controller RAM. Ack FAh is returned to the System if address range for Program execution was not violated. Otherwise error FFh is returned. 91h Execute Command 91h gets 2 byte of System Data: code-label LOW, HIGH and transfer control the specified address. The return addresses (passed in RAMAckRET and RAMErrRET variables) may be used by invoked routine to notify the System. 92h Read Boot Status Read Boot Status and combine it with Power Fail flag. AAh Self Test Since external KBC memory failure was detected, report error code FFh. D0h, D1H Read/Write GA20 D0h - Combine actual GateA20 state with emulated 8042 output port and send data to system. D1h - Only set/reset GateA20 line based on the system data bit 1. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |