![]() |
поискавой системы для электроныых деталей |
|
TPS658620ZQZT датащи(PDF) 68 Page - Texas Instruments |
|
|
TPS658620ZQZT датащи(HTML) 68 Page - Texas Instruments |
68 / 104 page ![]() 3.57.2 PEAK CURRENT CONTROL (BOOST CONVERTER) SM3 P(typ) MAX(L3) V I = I + 100 ns L ´ (3-6) 3.57.3 SOFTSTART 3.57.4 ENABLING THE SM3 CONVERTER TPS658620 Advanced Power Management Unit SLVS993 – OCTOBER 2009 www.ti.com Figure 3-19. SM3 Duty Cycle Example The repetition period can be set using control bits SM3_PRESCn in the register SM3_SET1 to either 220/275/366/550 Hz (HI). Each repetition period has a total of 2048 steps, enabling a resolution of 0.05% when programming the duty cycle. The SM3 integrated power stage switch is turned on until the inductor current reaches the DC current limit IMAX(L3) (500 mA or 300mA, typ), selectable via bit SM3_ILIM , register SM3_SET1. Due to internal delays, typically around 100ns, the actual current exceeds the DC current limit threshold by a small amount. The typical peak current limit can be calculated as follows: The peak current will be directly proportional to the input voltage and inversely proportional to the inductor value. The internal current limit may be set to either 300mA or 500mA via I2C. Note that under PWM operation the slew rate of the converter output (SM3) is dependent of the IMAX(L3) value selected. All inductive step-up converters exhibit high in-rush current during start-up. If no special precautions are taken voltage drops can be observed at the input supply rail during start-up, with unpredictable results in the overall system operation. The SM3 boost converter limits the inrush current during start-up by increasing the current limit in two steps, starting from IMAX(L3) /4 for 256 power stage switch cycles (1cycle=power stage switch OFF →ON→OFF) to I MAX(L3) /2 for the next 256 power stage switch cycles and then full current limit IMAX(L3). The softstart function can be disabled via control bit SM3SOFTOFF, in register SM3_SET1. The converter is enabled when an I2C command sets the duty cycle to a value different than zero. DETAILED DESCRIPTION 68 Submit Documentation Feedback |
Аналогичный номер детали - TPS658620ZQZT |
|
Аналогичное описание - TPS658620ZQZT |
|
|
ссылки URL |
Конфиденциальность |
ALLDATASHEETRU.COM |
Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |