| поискавой системы для электроныых деталей |
|
M38044F2HKP датащи(PDF) 275 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
M38044F2HKP датащи(HTML) 275 Page - Renesas Technology Corp |
|
275 / 387 page ![]() 2-151 APPLICATION 2.12 Standby function Rev.1.00 Jan 14, 2005 REJ09B0212-0100Z 3804 Group (Spec.H) sRestoration by interrupt request The occurrence of an interrupt request in the stop mode releases the stop mode. As a result, oscillation is resumed. The interrupts available for restoration are: •INT0–INT4 •CNTR0, CNTR1, CNTR2 •Serial I/O (1, 2, 3) using an external clock •Timer X, Y, Z using an external event count •SCL/SDA However, when using any of these interrupt requests for restoration from the stop mode, in order to enable the selected interrupt, you must execute the STP instruction after setting the following conditions. [Necessary register setting] ➀ Interrupt disable flag I = “0” (interrupt enabled) ➁ Timer 1 interrupt enable bit = “0” (interrupt disabled) ➂ Interrupt request bit of interrupt source to be used for restoration = “0” (no interrupt request issued) ➃ Interrupt enable bit of interrupt source to be used for restoration = “1” (interrupts enabled) For more details concerning interrupts, refer to “2.2 Interrupts”. Oscillation is unstable when restarted. For this reason, time for stabilizing of oscillation (oscillation stabilizing time) is required. For restoration by an interrupt request, waiting time prior to supplying internal clock φ to the CPU is automatically generated✽2 by Prescaler 12 and Timer 1✽1. This waiting time is reserved as the oscillation stabilizing time on the system clock side. The supply of internal clock φ to the CPU is started at the Timer 1 underflow. Figure 2.12.2 shows an execution sequence example at restoration by the occurrence of an INT0 interrupt request. ✽1: If the STP instruction is executed when the oscillation stabilizing time set after STP instruction released bit is “0”, “FF16” and “0116” are automatically set in the Prescaler 12 counter/latch and Timer 1 counter/latch, respectively. When the oscillation stabilizing time set after STP instruction released bit is “1”, nothing is automatically set to either Prescaler 12 or Timer 1. For this reason, any suitable value can be set to Prescaler 12 and Timer 1 for the oscillation stabilizing time. ✽2: Immediately after the oscillation is started, the count source is supplied to the prescaler 12 so that a count operation is started. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |