145 / 196 page ![]() 145/196 OPERATING CONDITIONS (Cont’d) 12.3.2 Operating Conditions with Low Voltage Detector (LVD) Subject to general operating conditions for VDD, fCPU, and TA. Notes: 1. Data based on characterization results, tested in production for ROM devices only. 2. If the medium or low thresholds are selected, the detection may occur outside the specified operating voltage range. Below 3.8V, device operation is not guaranteed. 3. Data based on characterization results, not tested in production. 12.3.3 Auxiliary Voltage Detector (AVD) Thresholds Subject to general operating conditions for VDD, fCPU, and TA. 1. Data based on characterization results, tested in production for ROM devices only. 12.3.4 External Voltage Detector (EVD) Thresholds Subject to general operating conditions for VDD, fCPU, and TA. 1. Data based on characterization results, not tested in production. Symbol Parameter Conditions Min Typ Max Unit VIT+(LVD) Reset release threshold (VDD rise) VD level = High in option byte 4.01) 4.2 4.5 V VD level = Med. in option byte2) VD level = Low in option byte2) 3.551) 2.951) 3.75 3.15 4.01) 3.351) VIT-(LVD) Reset generation threshold (VDD fall) VD level = High in option byte 3.8 4.0 4.251) VD level = Med. in option byte2) VD level = Low in option byte2) 3.351) 2.81) 3.55 3.0 3.751)) 3.15 1) Vhys(LVD) LVD voltage threshold hysteresis VIT+(LVD)-VIT-(LVD) 200 mV VtPOR VDD rise time 3) LVD enabled 6 µs/V 100ms/V tg(VDD) VDD glitches filtered (not detect- ed) by LVD 3) 40 ns Symbol Parameter Conditions Min Typ Max Unit VIT+(AVD) 1 ⇒0 AVDF flag toggle threshold (VDD rise) VD level = High in option byte 4.41) 4.6 4.91) V VD level = Med. in option byte VD level = Low in option byte 3.95 1) 3.4 1) 4.15 3.6 4.41) 3.81) VIT-(AVD) 0 ⇒1 AVDF flag toggle threshold (VDD fall) VD level = High in option byte 4.21) 4.4 4.65 1) VD level = Med. in option byte VD level = Low in option byte 3.751) 3.21) 4.0 3.4 4.2 1) 3.61) Vhys(AVD) AVD voltage threshold hysteresis VIT+(AVD)-VIT-(AVD) 200 mV ∆VIT- Voltage drop between AVD flag set and LVD reset activated VIT-(AVD)-VIT-(LVD) 450 mV Symbol Parameter Conditions Min Typ Max Unit VIT+(EVD) 1 ⇒0 AVDF flag toggle threshold (VDD rise) 1) 1.15 1.26 1.35 V VIT-(EVD) 0 ⇒1 AVDF flag toggle threshold (VDD fall) 1) 1.1 1.2 1.3 Vhys(EVD) EVD voltage threshold hysteresis VIT+(EVD)-VIT-(EVD) 200 mV |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |