133 / 152 page ![]() The information about the number of encountered WDT data failures is stored in the dedicated SPI register WDT_FAIL_COUNT_STATUS. Figure 88. WDT operation – Word sequence failure In case of failure (WDT_OVF_fail =1 or WDT_DATA_fail =1) the WDT can be reset by setting to10 the SPI register command WDT_RESET. Table 150. Watchdog RESET bits WDT_RST1 WDT_RST0 Description 0 0 NO reset 0 1 NO reset (Default) 1 0 Reset 1 1 NO reset Note: This command is processed by the logic only if a failure is detected (WDT_OVF_fail = 1 or WDT_DATA_fail = 1). The WDT_RESET does not reset the WDT_EN bit but only the error flag: µC needs to refresh the WDT properly afterwards. L9908 Functional description DS13546 - Rev 5 page 133/152 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|