PVT412L Datasheet with Chat AI
  • AIauthorized

    Hello, Please ask a question about PVT412L Datasheet

  • # Example questions: ➢ What should be carefully monitored to prevent damage to the input led, and what is the maximum allowable current?
    ➢ What is the minimum dielectric strength, in vrms, for all models of the pvt412 series?
    ➢ What is the maximum load current for the pvt412l when controlled with 5ma, specifically for connection a?

  • Part No.PVT412L
    ManufacturerIRF
    Size174 Kbytes
    Pages5 pages
    DescriptionMicroelectronic Power IC Relay Single Pole, Normally Open, 0-400V, 140mA AC/DC
    Datasheet Summary with AI

    1. Overview & Product Description

    ️· The document describes the IR (International Rectifier) Series PVT412 - a relay-like switching device. It's primarily used for applications requiring electrical isolation and switching.
    ️· It emphasizes that the product is *not* intended for use in aerospace, avionics, military, or life-support applications.

    2. Electrical Characteristics (Key Performance Metrics)


    Feature PVT412 PVT412L Units
    Operating Voltage Range 0 to ±400 0 to ±400 Volts (DC or AC Peak)
    Maximum Load Current (at 5mA Control Current) 120, 130, 200 120, 130, 200 Amps (AC or DC)
    Maximum On-State Resistance (for 50mA Pulsed Load, 5mA Control) 35, 18, 9 35, 18, 9 Ohms
    Maximum Off-State Leakage Current 1.0 1.0 µA
    Current Limit (for 5mA control) Minimum 130A, Maximum 220A 260A, 440A Amps
    Control Current Range 3.0 to 25 3.0 to 25 mA
    Maximum Reverse Voltage 7.0 7.0 Volts
    Turn-On Time 2.0 2.0 ms
    Turn-Off Time 0.5 0.5 ms
    Maximum Thermal Offset Voltage 0.5 0.5 µV
    Maximum Output Capacitance 12 12 pF

    3. Environmental Conditions

    ️· Operating Ambient Temperature Range: -40°C to +85°C.
    ️· Storage Ambient Temperature Range: -40°C to +100°C.

    4. Figures & Diagrams (Referenced)

    ️· Figure 1: Current Derating Curves: Shows how the maximum load current changes with temperature. Important for ensuring proper operation at different ambient temperatures.
    ️· Figure 2: Current Derating Curves: Another view of current limits based on temperature.
    ️· Figure 3: Linearity Characteristics: Likely shows a characteristic curve related to the relay’s output response.
    ️· Figure 4: Typical Normalized On-Resistance: Likely shows the on-resistance of the relay as a function of some parameter (potentially current or voltage).
    ️· Figure 5: Typical Normalized Off-State Leakage: Illustrates the leakage current under different conditions.
    ️· Figure 6: Input Characteristics (Current Controlled): Shows how the control current influences the relay's behavior.
    ️· Figure 7: Typical Delay Times: Shows the turn-on and turn-off times.
    ️· Figure 8: Delay Time Definitions: Clarifies the timing parameters.
    ️· Figure 9: Typical Output Capacitance: Likely shows how the output capacitance varies.

    5. Key Notes & Cautions

    ️· Current Limiting: A prominent caution advises that a current-limiting circuit must be used to protect the control input and ensure reliable operation. The control current should not exceed 25mA.
    ️· Temperature Derating: The load current must be derated at higher temperatures (as indicated in the current derating curves) to prevent damage or malfunction.
    ️· Application Restrictions: The device is not suitable for critical applications where failure could result in serious harm.

    6. Contact Information

    ️· IR World Headquarters Address & Phone Number: Provided for further inquiries.

    1. Overview & Product Description

    ️· The document describes the IR (International Rectifier) Series PVT412 - a relay-like switching device. It's primarily used for applications requiring electrical isolation and switching.
    ️· It emphasizes that the product is *not* intended for use in aerospace, avionics, military, or life-support applications.

    2. Electrical Characteristics (Key Performance Metrics)


    Feature PVT412 PVT412L Units
    Operating Voltage Range 0 to ±400 0 to ±400 Volts (DC or AC Peak)
    Maximum Load Current (at 5mA Control Current) 120, 130, 200 120, 130, 200 Amps (AC or DC)
    Maximum On-State Resistance (for 50mA Pulsed Load, 5mA Control) 35, 18, 9 35, 18, 9 Ohms
    Maximum Off-State Leakage Current 1.0 1.0 µA
    Current Limit (for 5mA control) Minimum 130A, Maximum 220A 260A, 440A Amps
    Control Current Range 3.0 to 25 3.0 to 25 mA
    Maximum Reverse Voltage 7.0 7.0 Volts
    Turn-On Time 2.0 2.0 ms
    Turn-Off Time 0.5 0.5 ms
    Maximum Thermal Offset Voltage 0.5 0.5 µV
    Maximum Output Capacitance 12 12 pF

    3. Environmental Conditions

    ️· Operating Ambient Temperature Range: -40°C to +85°C.
    ️· Storage Ambient Temperature Range: -40°C to +100°C.

    4. Figures & Diagrams (Referenced)

    ️· Figure 1: Current Derating Curves: Shows how the maximum load current changes with temperature. Important for ensuring proper operation at different ambient temperatures.
    ️· Figure 2: Current Derating Curves: Another view of current limits based on temperature.
    ️· Figure 3: Linearity Characteristics: Likely shows a characteristic curve related to the relay’s output response.
    ️· Figure 4: Typical Normalized On-Resistance: Likely shows the on-resistance of the relay as a function of some parameter (potentially current or voltage).
    ️· Figure 5: Typical Normalized Off-State Leakage: Illustrates the leakage current under different conditions.
    ️· Figure 6: Input Characteristics (Current Controlled): Shows how the control current influences the relay's behavior.
    ️· Figure 7: Typical Delay Times: Shows the turn-on and turn-off times.
    ️· Figure 8: Delay Time Definitions: Clarifies the timing parameters.
    ️· Figure 9: Typical Output Capacitance: Likely shows how the output capacitance varies.

    5. Key Notes & Cautions

    ️· Current Limiting: A prominent caution advises that a current-limiting circuit must be used to protect the control input and ensure reliable operation. The control current should not exceed 25mA.
    ️· Temperature Derating: The load current must be derated at higher temperatures (as indicated in the current derating curves) to prevent damage or malfunction.
    ️· Application Restrictions: The device is not suitable for critical applications where failure could result in serious harm.

    6. Contact Information

    ️· IR World Headquarters Address & Phone Number: Provided for further inquiries.

    Part No.PVT412L
    ManufacturerIRF
    Size174 Kbytes
    Pages5 pages
    DescriptionMicroelectronic Power IC Relay Single Pole, Normally Open, 0-400V, 140mA AC/DC
    Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

    Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
    All Rights Reserved©Alldatasheet.com


    Mirror Sites
    English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
    Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
    Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
    Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
    Family Site : ic2ic.com  |   icmetro.com