1. Electrical Characteristics & Specifications
| Part Number |
Inductance (µH) |
Test Frequency (Hz) |
DCR (mΩ) |
Irms (A) |
| SSL1308M-R21MF-R32 |
0.21 ± 20% |
0.25V/1M |
0.32 |
45 |
| SSL1308M-R26MF-R32 |
0.26 ± 20% |
0.25V/1M |
0.32 |
45 |
| SSL1308M-R32MF-R32 |
0.32 ± 20% |
0.25V/1M |
0.32 |
41 |
| SSL1308M-R44MF-R32 |
0.44 ± 20% |
0.25V/1M |
0.32 |
30 |
| SSL1308M-R21MF-R53 |
0.21 ± 20% |
0.25V/1M |
0.53 |
45 |
| SSL1308M-R26MF-R53 |
0.26 ± 20% |
0.25V/1M |
0.53 |
45 |
| SSL1308M-R53MF-R53 |
0.32 ± 20% |
0.25V/1M |
0.53 |
41 |
| SSL1308M-R44MF-R53 |
0.44 ± 20% |
0.25V/1M |
0.53 |
30 |
2. Reliability Test Specifications ️· High-Temperature Life Test:
- Conditions: Time: 500 ± 12 hours; Temperature: 125 ± 5 °C
- Acceptance Criteria:
■ Inductance within ±20% of initial value.
■ No disconnection or short circuit.
■ No visible damage.
️· Low-Temperature Life Test:
- Conditions: Time: 500 ± 12 hours; Temperature: -40 ± 5 °C
️· Thermal Shock:
- Conditions: Cycles: 5; Temperature Profile: -25 ± 3 °C → Room Temperature → 85 ± 3 °C → Room Temperature
- Steps:
1. -25 ± 3 °C for 30 ± 3 minutes.
2. Room Temperature for within 3 minutes.
3. 85 ± 3 °C for 30 ± 3 minutes.
4. Room Temperature for within 3 minutes.
️· Humidity Resistance:
- Conditions: Time: 500 ± 12 hours; Temperature: 40 ± 5 °C; Humidity: 90% to 95%
- Acceptance Criteria:
■ Inductance within ±20% of initial value.
■ No disconnection or short circuit.
■ No visible damage.
️· Random Vibration Test:
- Conditions: Frequency: 10-55-10 Hz; Duration: 1 minute; Direction: X, Y, Z (2 hours each)
- Acceptance Criteria: No defects harmful to characteristics, no visible damage.
3. Tape & Reel Specifications (For Automated Assembly)
| Dimension |
Value |
| Width (A) |
13.46 Max |
| Width (B) |
12.95 Max |
| Width (G) |
3.18 ± 0.25 |
| Width (H) |
7.11 ± 0.25 |
| Width (I) |
7.62 ± 0.25 |
| Type A (mm) |
|
| B(mm) |
24.0 ± 0.5 |
| C(mm) |
13.5 ± 0.5 |
| D(mm) |
330 |
| Series |
Ao (mm) |
Bo (mm) |
Ko (mm) |
P (mm) |
W (mm) |
t (mm) |
| SSL1308M |
13.8 ± 0.1 |
8.2 ± 0.1 |
16.0 ± 0.1 |
24.0 ± 0.3 |
0.35 ± 0.05 |
|
4. Tearing Force of Cover Tape
| Room Temp. (°C) |
Room Humidity (%) |
Room atm (hPa) |
Tearing Speed (mm/min) |
| 5-35 |
45-85 |
860-1060 |
300 |
Key Improvements & Notes: ️· Organization: I've broken down the data into logical sections.
️· Tables: Tables are used to present numerical data in a clear, easy-to-read format.
️· Clarity: I've reworded some descriptions for better understanding.
️· Completeness: All data points from the text have been included.
️· Units: Units of measurement are clearly indicated.