| поискавой системы для электроныых деталей |
|
The question interval is too short.
Please try again in a few seconds.
Hello, Please ask a question about AM22CWCMBAR/1500B Datasheet
# Example questions:
➢ What is the accuracy of the am2-tc1 module when reading temperature, and what factors influence this accuracy?
➢ What thermocouple types are supported by the am2-tc1 module?
➢ Can the ate-2 be used to measure both temperature and pressure simultaneously, and if so, what additional modules would be required?
1. General Information & Pressure Measurement:
️· Product: ATE-2 Handheld Calibrator
️· Function: A portable device for calibrating pressure and temperature instruments.
️· Pressure Measurement details (not fully detailed, but mentions):
- Broad range of pressure types and units.
- High accuracy.
- Multiple pressure connections. (Likely includes various adapters for different fittings).
2. RTD (Resistance Temperature Detector) Temperature Measurement:
️· Module Needed: AM2-RTD interface module
️· Units: °C, °F, °K, °R
️· Resolution: 1, 0.1, or 0.01 degrees selectable, or "Auto" mode (chooses best resolution)
️· Accuracy: Not explicitly stated in this excerpt, but would be a key specification.
️· Important: Requires customer-supplied RTD probes.
3. Thermocouple Temperature Measurement:
️· Module Needed: AM2-TC1 interface module
️· Thermocouple Types: Supports 8 common thermocouple types (specific types not listed).
️· Reference Junctions: Can use internal or external reference junctions.
️· Units: °C, °F, °K, °R, millivolts
️· Resolution: 1, 0.1, or 0.01 degrees selectable, or "Auto" mode. 0.001 millivolts for millivolt readings.
️· Connection: Requires miniature thermocouple connectors (Omega type SMP).
️· Important: Requires customer-supplied thermocouple probes.
️· Accuracy: System accuracy includes base unit and interface module (but doesn't include thermocouple probe inaccuracy - consult manufacturer specs).
️· Conversion Factors: Provided for converting between temperature scales.
4. General Specifications & Notes:
️· Accuracy: Accuracy is a critical specification, and while mentioned as system accuracy for temp measurements, specific numbers would be in the full datasheet.
️· Manual/Automatic Modes: Often selectable for reference junctions and resolution.
️· Customer-Supplied Probes: RTDs and thermocouples are *not* included with the calibrator; users must provide their own.
️· Subject to Change: All specifications are subject to change without notice.
️· Conversion Factors: Conversion from Celsius to Fahrenheit, Kelvin and Rankine
Overall Impression:
1. General Information & Pressure Measurement:
️· Product: ATE-2 Handheld Calibrator
️· Function: A portable device for calibrating pressure and temperature instruments.
️· Pressure Measurement details (not fully detailed, but mentions):
- Broad range of pressure types and units.
- High accuracy.
- Multiple pressure connections. (Likely includes various adapters for different fittings).
2. RTD (Resistance Temperature Detector) Temperature Measurement:
️· Module Needed: AM2-RTD interface module
️· Units: °C, °F, °K, °R
️· Resolution: 1, 0.1, or 0.01 degrees selectable, or "Auto" mode (chooses best resolution)
️· Accuracy: Not explicitly stated in this excerpt, but would be a key specification.
️· Important: Requires customer-supplied RTD probes.
3. Thermocouple Temperature Measurement:
️· Module Needed: AM2-TC1 interface module
️· Thermocouple Types: Supports 8 common thermocouple types (specific types not listed).
️· Reference Junctions: Can use internal or external reference junctions.
️· Units: °C, °F, °K, °R, millivolts
️· Resolution: 1, 0.1, or 0.01 degrees selectable, or "Auto" mode. 0.001 millivolts for millivolt readings.
️· Connection: Requires miniature thermocouple connectors (Omega type SMP).
️· Important: Requires customer-supplied thermocouple probes.
️· Accuracy: System accuracy includes base unit and interface module (but doesn't include thermocouple probe inaccuracy - consult manufacturer specs).
️· Conversion Factors: Provided for converting between temperature scales.
4. General Specifications & Notes:
️· Accuracy: Accuracy is a critical specification, and while mentioned as system accuracy for temp measurements, specific numbers would be in the full datasheet.
️· Manual/Automatic Modes: Often selectable for reference junctions and resolution.
️· Customer-Supplied Probes: RTDs and thermocouples are *not* included with the calibrator; users must provide their own.
️· Subject to Change: All specifications are subject to change without notice.
️· Conversion Factors: Conversion from Celsius to Fahrenheit, Kelvin and Rankine
Overall Impression:
| Part No. | AM22CWCMBAR/1500B |
| Manufacturer | ASHCROFT |
| Size | 2Mb |
| Pages | 9 pages |
| Description | ATE-2 Handheld Calibrator |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |